MVI56E-MCM ControlLogix Configuration Communication Module

¥2,180.00

The MVI56E-MCM additional instruction needs to be version 2.8 or higher

Category: SKU: MVI56E-MCM Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Make sure your ControlLogix processor and power supply are installed and configured, before installing the MVI56E-MCM module. Refer to your Rockwell Automation product documentation for installation instructions.

Warning: You must follow all safety instructions when installing this or any other electronic devices. Failure to follow safety procedures could result in damage to hardware or data, or even serious injury or death to personnel. Refer to the documentation for each device you plan to connect to verify that suitable safety procedures are in place before installing or servicing the device.

After you have checked the placement of the jumpers, insert the MVI56E-MCM into the ControlLogix chassis. Use the same technique recommended by Rockwell Automation to remove and install ControlLogix modules. You can install or remove ControlLogix system components while chassis power is applied and the system is operating. However, please note the following warning.

 

In the NEW MODULE dialog box, enter the following values.
Parameter Value
Name MCM
Description Enter a description for the module. Example: Modbus
Communication Module
Comm Format Select DATA-INT
Slot Enter the slot number in the rack where the MVI56E-MCM
module is located
Input Assembly Instance 1
Input Size 250
Output Assembly Instance 2
Output Size 248
Configuration Assembly Instance 4
Configuration Size 0

 

The module internal database is divided into two user-configurable areas:

· Read Data

· Write Data.

The Read Data area is moved from the module to the processor, while the Write Data area is moved from the processor to the module. You can configure the start register and size of each area. The size of each area you configure must match the Add-On Instruction controller tag array sizes for the READDATA and WRITEDATA arrays. The MVI56E-MCM sample program is configured for 600 registers of READDATA and 600 registers of WRITEDATA, which is sufficient for most application. This topic describes how to configure user data for applications requiring more than 600 registers of ReadData and WriteData. In this example, we will expand both the Read and Write Data sizes to 1000.

MVI56E-MCM Product specifications
The product structure is small and rail mounted, which can be installed with high density
Connection method 8mm wiring terminal
The material of the terminal screw is nickel plated on the iron surface, and the allowable torque of the screw is less than 0.8N · m
The casing material of the DC isolator is made of fire-resistant resin
Isolation channel insulation, between input output power supply
The power indicator light is green LED, which lights up when the power is supplied