PLX31-MBTCP-MBS4 ASCII Network Interface Module PROSOFT

¥2,180.00

Product: PLX31-MBTCP-MBS4
Output frequency: standard kHz
System environment: stable
System capability: normal
Operating system: DCS/PLC system

Category: SKU: PLX31-MBTCP-MBS4 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application.

In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance.

 

PLX31-MBTCP-MBS4 technical parameter
a) Accuracy level: 0.2, 0.5
b) Input, output, and auxiliary power supply parameters
c) Input frequency: 50Hz ± 5Hz
d) Overload input: Current: 2 times continuous 30 times for 1 second
Voltage: 2 times continuous
e) Absorbed power: Voltage circuit: < 0 5VA/450V
Voltage circuit: < 0.2VA/100V
Current circuit: < 0.1 VA/5A
f) Response time: ≤ 350ms
g) Output load: Current: When the auxiliary power supply is ≥ 24V, RL ≤ 650 Ω;
When the auxiliary power supply is+12V or+15V, RL ≤ 300 Ω;
Voltage: RL ≥ 2k Ω
h) Power frequency withstand voltage: input/output/between enclosures: AC 2kV/min
i) Insulation resistance: ≥ 20M Ω
j) Impulse voltage: 5kV/1.2-50 μ S (peak)
k) Working environment: Temperature: -10~50 ℃ Humidity: 10~90% (without condensation)
l) Storage conditions: Temperature: -40~70 ℃ Humidity: 10~95% (without condensation)

 

 

PLX31-MBTCP-MBS4 Features :

Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data, optimizing Ethernet bandwidth. ¨

Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time. ¨

Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery. ¨

Four serial ports allow for connectivity of up to 400 Modbus® devices, reducing the amount of gateways required for your application. ¨

ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet. ¨ Secure module configuration via module switch (v1.04 and greater). ¨

Up to 10,000 16-bit registers can be used to exchange large amounts of data.