Components in the IMR6000/10 system framework

¥2,180.00

Model Number: IMR6000/10

reference temperature:
+25°C / +77°F

nominal use range:
0 … +65°C / 32 … +167° F

EMC:
regarding EN50 081−1 / EN50 082−2

Category: SKU: IMR6000/10 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

The system frames IMR 6000/10 ../20 ../30 are developed for general use in industrial applications, where reliable adaptations between electronic devices and plant devices are necessary. With the system frames IMR 6000/10, ../20, ../30, an appropriate adaptation of the signal processing periphery like: − alarm signals − error signals − connection results − external signals can be realized and processed to feed in and spend out all relevant signals.

The system frames IMR 6000/10, ../20, ../30 are components of the epro MMS 6000 machine monitoring system. They consist of a 19” card frame and comprise the following card slots at the front side: • 8−10 Monitor slots (depending on the IMR type) for monitors of the MMS 6000 series • 2−4 slots (depending on the IMR type) for adaptation of one or more logic cards e.g. MMS 6740 • 1 slot for adaptation of an interface card e.g. MMS 6830, MMS 6831, MMS 6824 or MMS 6825 The first monitor slot at the system frames IMR6000/10 and IMR6000/30 offers the possibility to imply a key monitor (MMS 6310 or MMS 6312) and to relay these key signals to other monitors via the system frame or external connections.

The rear of the system frames IMR 6000/10, ../20, ../30 serve the purpose of:

• signal supply

• signal output for further processing

• parameterization of the system frame The connection to the external periphery at the rear of the system frame is made by spring cage− or screw connection plugs.

If neccessary, it is possible to build up several RS485 bus lines within one system frame by the integration of a corresponding interface card. The appropriate parameterization does take place via external connections and/or via the configuration of the regarding Dip− switches. The system frames IMR 6000/10, ../20, ../30 offer substantial saving potential with the wiring complexity.

 

The system frame IMR 6000/10 comprises the following card slots at the front side: • 10 slots for monitors of the MMS 6000 series * • 2 slots for adaptation of one logic card e.g. MMS 6740 • 1 slot for connection of an interface card e.g. MMS 6830, MMS 6831, MMS 6824 or MMS 6825 The following monitors are supported by the system frame IMR 6000/10 with their basic functions: MMS 6110, MMS 6120, MMS 6125 MMS 6140, MMS 6210, MMS 6220 MMS 6310, MMS 6312, MMS 6410 The connection of the external periphery at the rear of the system frame is made by 5− and 8− pole spring cage− or screw terminal connection plugs (Phoenix).

 

The RS485− bus connections, the respective key connection as well as all channel clear, alert and danger alarms of the monitors are carried out via these plugs. The voltage supply plugs at the rear of the system frame can be made by 5−pole spring cage− or screw terminal connection plugs. The 1st monitor slot at the system frame offers the possibility to imply a key monitor and to relay its key signals to the other monitors. On the one hand the interface card offers the option of direct connection to a RS485 bus via Dip− switch configuration and, in addition, the possibility to connect the monitors to the RS 485 bus by external wiring at the plugs. On the basis of the implemented Dip switches, the RS485−Bus can be configured accordingly