NI PXI-2510 (NI 2510) Matrix Relay Card

¥5,900.00

Cable for NI PXI-2510 (To 3, 50-pin D-SUB) 781090-01
Cable for NI PXI-2510 (To 160-pin DIN) 781090-02
Cable for NI PXI-2510 (To Bare Wire) 781090-03

Category: SKU: PXI-2510 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

NI PXI-2510 (NI 2510) Matrix Relay Card

 

Dynamic Characteristics
Relay Operate Time4
………………………………………………………….. Typical 1 ms
………………………………………………………….. Maximum 3 ms
…………………………………………………………………. Expected mechanical relay life 1×108
cycles
Expected electrical relay life
………………………………………………………….. 30 V, 1 A 5×105
cycles
………………………………………………………….. 30 V, 2 A 1×105
cycles

 

Physical Characteristics
…………………………………………………………………. Relay type Electromechanical, non-latching
…………………………………………………………………. Relay contact material Palladium-ruthenium, gold covered
…………………………………………………………………. Front panel connector 160 DIN 41612, 160 positions, male
Power requirement
PXI
…………………………………………………… 5 V, typical 6.6 W
…………………………………………………… 3.3 V, typical 0.48 W
…………………………………………………………………. Dimensions (L × W × H) 3U, one slot, PXI/cPCI module, 18.8 cm ×
2.0 cm × 13.0 cm (7.4 in. × 0.8 in. × 5.1 in.)
…………………………………………………………………. Weight 358 g (12.6 oz)

 

Caution This module is rated for Measurement Category I and intended to carry signal voltages no greater than 150 V. This module can withstand up to 500 V impulse voltage. Do not use this module for connection to signals or for measurements within Categories II, III, or IV. Do not connect to MAINs supply circuits (for example, wall outlets) of 115 or 230 VAC.