NI PXI-4060 Converter (ADC)

¥5,900.00

NI 4060 first AC-couples the measured signal to remove any DC components and then measures the RMS value of the AC component.

Category: SKU: PXI-4060 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

NI PXI-4060 Converter (ADC)

 

Introduction: When operating the NI 4060 instrument, it is crucial to adhere to safety guidelines to ensure both user safety and the integrity of the equipment. The following guidelines outline essential precautions and procedures for the proper use of this instrument.

 

Section 1: Environmental Considerations 1.1 Avoid Explosive Atmospheres: Never operate the instrument in an explosive atmosphere or areas with flammable gases or fumes. This precaution is essential to prevent potential hazards.

1.2 Installation Category II Environment: The equipment specified in this document must be used in an Installation Category II environment as per IEC 664, requiring a local level supply mains-connected installation.

Section 2: Voltage Limitations 2.1 Maximum Voltage: To prevent safety hazards, ensure that the maximum voltage between any input and the ground of the computer does not exceed ±300 VDC or 300 Vrms.

Section 3: Chassis and Equipment Requirements 3.1 NRTL-Listed Chassis or Personal Computer: The NI 4060 must be used in a chassis or personal computer that is Nationally Recognized Testing Laboratory (NRTL)-listed to maintain safety standards.

3.2 Avoid Operating Damaged Equipment: Under no circumstances should you operate damaged equipment. The safety protection features may be compromised if the instrument is damaged.

Section 4: Instrument Maintenance and Repairs 4.1 Safety Check after Damage: If the instrument is damaged, refrain from using it until service-trained personnel can perform a safety check. If necessary, return the instrument to National Instruments for service and repair to ensure safety is not compromised.

4.2 Compliance with Specifications: Do not operate the instrument in a manner that contradicts the information specified in this document. Misuse could lead to a shock hazard.

Section 5: Parts Substitution and Modifications 5.1 Avoid Parts Substitution or Modifications: Do not substitute parts or modify the equipment. Unauthorized modifications or substitutions can introduce additional hazards. In case of any issues, return the instrument to National Instruments for proper service and repair to maintain safety standards.

 

Conclusion: Adhering to these safety guidelines is paramount to the proper functioning of the NI 4060 instrument and, more importantly, the safety of the user. Following these precautions will help prevent potential hazards and ensure the longevity of the instrument.

Title: Optimizing Measurement Accuracy with Proper Warm-Up Procedures for NI 4060

Introduction: Ensuring accurate measurements with the NI 4060 multimeter requires attention to the instrument’s warm-up time. This article provides essential information on the warm-up process and its impact on measurement accuracy.

Section 1: Understanding Thermal Drift 1.1 Importance of Warm-Up Time: The NI 4060 requires a 30-minute warm-up time before accurate measurements can be obtained. This crucial warm-up period is necessary due to potential changes in measurements caused by thermal drift.

1.2 Thermal Drift and Temperature Coefficients: Thermal drift is the alteration in measurements influenced by temperature changes. Temperature coefficients play a role in this phenomenon. It is imperative to acknowledge these factors when aiming for precise measurements.

Section 2: Minimizing Thermal Drift for Accurate Measurements 2.1 Significance of Full Warm-Up: To mitigate the effects of thermal drift and ensure specified accuracies, it is recommended to take all measurements after the NI 4060 has undergone a complete warm-up.

2.2 Operating Temperature Range: The NI 4060 can operate significantly above ambient temperature depending on the environment. Immediate measurements after powering up may differ substantially from those taken after the instrument has fully warmed up.

Section 3: Temperature Coefficient Specifications 3.1 Reference to Accuracy Sections: For detailed information on temperature coefficients and their impact on accuracy, refer to the Accuracy sections in Appendix A. This provides specific NI 4060 temperature coefficient specifications.

Conclusion: Understanding and adhering to the warm-up time requirement is essential for optimizing the accuracy of measurements with the NI 4060 multimeter. By following these guidelines, users can minimize the effects of thermal drift and ensure precise readings in various environmental conditions.