GDD360C 3BHE047217R0101 Power Module

 

GDD360C 3BHE047217R0101 CT-S Range Technical Data:

Input Circuit – Supply Circuit:

  • Rated Control Supply Voltage:
    • CT-xxx.x1: 24-240 V AC/DC
    • CT-xxx.x2: 24-48 V DC, 24-240 V AC
    • CT-xxx.x3: 380-440 V AC
  • Rated Control Supply Voltage Tolerance: -15% to +10%
  • Rated Frequency: DC or 50/60 Hz (AC)
  • Frequency Range: 47-63 Hz (AC)
  • Typical Power Consumption: Max. 16 VA
  • Power Failure Buffering Time:
    • 24 V DC: Min. 15 ms
    • 230/400 V AC: Min. 20 ms
  • Release Voltage: > 10% of the minimum rated control supply voltage Us
  • Minimum Energizing Time: 100 ms (CT-ARS)
  • Formatting Time: 5 min (CT-ARS)

GDD360C 3BHE047217R0101 Input Circuit – Control Circuit:

  • Kind of Triggering: Voltage-related triggering
  • Control Input, Control Function:
    • A1-Y1/B1 start timing external (CT-MVS, CT-MXS, CT-APS)
    • Y1-Z2 start timing external / X1-Z2 pause timing / accumulative functions (CT-MFS)
  • Parallel Load / Polarized: Yes / No
  • Maximum Cable Length to Control Input: 50 m (100 pF/m)
  • Minimum Control Pulse Length: 20 ms
  • Control Voltage Potential: See rated control supply voltage
  • Current Consumption of Control Input:
    • 24 V DC: 1.2 mA
    • 230 V AC: 8 mA
    • 400 V AC: 6 mA

GDD360C 3BHE047217R0101 Remote Potentiometer:

  • Resistance Value: Z1-Z2: 50 kΩ (CT-MFS, CT-MBS, CT-MVS.21, CT-MXS) / Z3-Z2: 50 kΩ (CT-MXS)
  • Maximum Cable Length to Remote Potentiometer: 2 x 25 m (shielded with 100 pF/m)
  • Shield Connection: Z2

GDD360C 3BHE047217R0101 Timing Circuit:

  • Time Ranges: 10 time ranges (0.05 s – 300 h)
  • Recovery Time:
    • 24-240 V AC/DC: < 50 ms
    • 24-48 V DC, 24-240 V AC: < 80 ms
    • 380-440 V AC: < 60 ms
  • Accuracy:
    • Within rated control supply voltage tolerance: < 0.004% / V
    • Within temperature range: < 0.03% / °C
  • Repeat Accuracy (Constant Parameters): < ±0.2%
  • Setting Accuracy of Time Delay: ±6% of full-scale value

Star-Delta Transition Time:

  • Fixed Time: 50 ms (CT-SDS, CT-MBS, CT-MFS, CT-MVS.2x)
  • Tolerance: ±2 ms

Note: Refer to the provided manual for additional information and specific configurations.