GVC736CE101 3BHE039203R0101 5SXE12-0184 Logic Controller

¥36,580.00

GVC736CE101 3BHE039203R0101 5SXE12-0184

Material: GVC736CE101 3BHE039203R0101 5SXE12-0184
Support: Hot swappable
Sale: Global
Service: Dianlian/WhatsApp
Size: Factory standard
Weight: 1KG
Warranty: 365 days

Additional information: Gop2 g2010 a 10.4st display screen panel

Category: SKU: GVC736CE101 3BHE039203R0101 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

GVC736CE101 3BHE039203R0101 5SXE12-0184 Logic Controller

 

GVC736CE101 3BHE039203R0101 5SXE12-0184 Technical specifications:
(1) The Modbus to Profibus gateway has two functions on the Modbus side: the MM function gateway is a slave station on the PROFIBUS-DP side and the Modbus master station on the Modbus side; The gateway of MS function is a slave station on the PROFIBUS-DP side and a Modbus slave station on the Modbus side; The interface achieves transparent communication between PROFIBUS and Modbus through data mapping between the PROFIBUS communication data area and the Modbus data area;
(2) Whether as a Modbus master or slave, it supports Modbus 01H, 02H, 03H, 04H, 05H, 06H, 0FH, and 10H functions;
(3) PROFIBUS-DP protocol, compliant; JB/T 10308.3-2001: Digital data communication for measurement and control – Fieldbus for industrial control systems – Part 3: PROFIBUS specification;
(4) Standard PROFIBUS-DP driver interface, baud rate adaptive, maximum baud rate 12M;
(5) The number of inputs/outputs on the PROFIBUS side can be freely set by the user within the following three ranges:
① Input Bytes+Output Bytes ≤ 232 Bytes;
② Max Input Bytes ≤ 224 Bytes;
③ Max Output Bytes ≤ 224 bytes.
(6) Standard RS-232/485 interface, half duplex, with optional baud rates of 2400, 4800, 9600, 19.2K, 38.4K, and 57.6K; Check bits (even, odd, none) are optional;
(7) RS232/485 maximum communication message length: send 230 bytes, receive 230 bytes;
(8) Wide voltage power supply: 10-30VDC, 200mA;
(9) Working environment temperature: -20-65 ℃;
(10) Storage temperature: -40~80 ℃;
(11) Relative humidity: ≤ 90% (non condensing);
(12) Installation: 35mm guide rail;
(13) Protection level: IP20.
(14) Product size: 40x110x74 (mm)

The 6’7″ handle rule, as stipulated in the National Electrical Code (Article 240.24), mandates that circuit breakers must be installed so that the center of the operating handle is not positioned higher than 6’7″ above the floor or working platform, whichever is greater. Housekeeping pads that elevate switchboards above the standing surface might infringe upon this regulation. In such cases, extending the pad to ensure compliance with the full working space may be necessary.

To determine if a device can be installed within the distribution section while adhering to the 6’7″ handle rule, two methods can be employed:

Method 1 – Measuring Mounting Location on Physical Section:

  1. Measure the distance from the floor (or working platform, if different from floor height) to the bottom of the desired mounting location (designated as dimension A).
  2. Check the measured dimension against the values provided in the table below. If the measured dimension does not exceed the specified value, the installation complies with the 6’7″ handle rule.

It’s essential to ensure that device mounting locations are in accordance with these regulations to maintain safety and compliance with electrical codes.

Please note: Since the table mentioned in Method 1 is not provided, specific values for compliance cannot be determined without further information from the relevant guidelines or standards.

 

Application scope:

 

Company environment: