Input output excitation controller module 3BSE008844R1

¥65,452.00

External connections:
• Excitation current to the load cells
• 2 or 4 analog inputs for load cell signals
• 4 analog outputs, voltage or current
• 8 digital inputs for control signals
• 8 digital outputs
• +24 V supply for external units, max 0.5 A
• Ethernet connection
• Service and multiple control units
• 2 serial interfaces of type RS-232 for
external displays, control, etc.

Model:3BSE008844R1

Category: SKU: 3BSE008844R1 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Input output excitation controller module 3BSE008844R1

Input output excitation controller module 3BSE008844R1

 

RED670 is used for the protection, control and monitoring of overhead lines and cables in all types of networks. The IED can be used from distribution up to the highest voltage levels. It is suitable for the protection of heavily loaded lines and multiterminal lines where the requirement for tripping is one-, two-, and/or three-phase.
The IED is also suitable for protection of cable feeders to generator block transformers.
The phase segregated current differential protection provides an excellent sensitivity for high resistive faults and gives a secure phase selection. The availability of six stabilized current inputs per phase allows use on multi-breaker arrangements in three
terminal applications or up to five terminal applications with single breaker arrangements. The communication between the IEDs involved in the differential
scheme is based on the IEEE C37.94 standard and can be duplicated for important installations when required for redundancy reasons. Charging current compensation allows high sensitivity also on long overhead lines and cables.
A full scheme distance protection is included to provide independent protection in parallel with the differential scheme in case of a communication channel failure for the differential scheme. The distance protection then provide protection for the entire line
including the remote end back up capability either in case of a communications failure or via use of an independent communication channel to provide a fully redundant scheme of protection (that is a second main protection scheme). Eight channels for intertrip and other binary signals are available in the communication between the IEDs.

 

 

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

 

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

 

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

 

Related models:

PFEA111-20 3BSE050090R20
PFEA111-65 3BSE050090R65
PFEA112-20 3BSE030369R0020
PFEA112-20 3BSE050091R20
PFEA112-65 3BSE050091R65
PFEA113-20 3BSE028144R0020
PFEA113-20 3BSE050092R20
PFEA113-65 3BSE028144R0065
PFEA113-65 3BSE050092R65
PFSA101 3BSC730179R1
PFSA103B EXCYM322001-EN
PFSA103C 3BSE002488R1
PFSA103D 3BSE002492R0001
PFSA103D 3BSE016268R1
PFSA103E 3BSE006503R1