Piezomagnetic tension sensor 3BSE004160R1

¥32,478.00

External connections:
• Excitation current to the load cells
• 2 or 4 analog inputs for load cell signals
• 4 analog outputs, voltage or current
• 8 digital inputs for control signals
• 8 digital outputs
• +24 V supply for external units, max 0.5 A
• Ethernet connection
• Service and multiple control units
• 2 serial interfaces of type RS-232 for
external displays, control, etc.

Model: 3BSE004160R1

Category: SKU: 3BSE004160R1 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Piezomagnetic tension sensor 3BSE004160R1

Piezomagnetic tension sensor 3BSE004160R1

 

The operation of high impedance earthed networks is different compared to solid earthed networks where all major faults have to be cleared very fast. In high impedance earthed networks, some system operators do not clear single phase-toearth faults immediately; they clear the line later when it is more convenient.

In case of cross-country faults, many network operators want to selectively clear one of the two earth faults. To handle this type phenomena Phase preference logic function (PPLPHIZ) is needed, which is not common to be used in transmission applications.

In this type of network, it is mostly not possible to use distance protection for detection and clearance of earth faults. The low magnitude of the earth-fault current might not give start of the zero-sequence measurement element or the sensitivity will be too low for acceptance. For this reason a separate high sensitive earth-fault prot

General Introduction of parallel lines in the network is increasing due to difficulties to get necessary area for new lines. Parallel lines introduce an error in the measurement due to the mutual coupling between the lines.

The lines need not to be of the same voltage in order to experience mutual coupling, and some coupling exists even for lines that are separated by 100 meters or more. The reason to the introduced error in measuring due to mutual coupling is the zero sequence voltage inversion that occurs. It can be shown from analytical calculations of line impedances that the mutual impedances for positive and negative sequence are very small and it is a practice to neglect them

 

 

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

 

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

 

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

 

Related models:

PFSK113 7625013-S
PFSK130 3BSE002616R1
PFSK151 3BSE018876R1
PFSK152 3BSE018877R1
PFSK152 3BSE018877R2
PFSK160A 3BSE009514R1
PFSK162 3BSE015088R1
PFSK164 3BSE021180R1
PFTL101A 0.5KN 3BSE004160R1
PFTL101A 0.5KN 3BSE004172R1
PFTL101A 1.0KN 3BSE004166R1
PFTL101A 2.0KN 3BSE004172R1
PFTL101A 2.0KN 3BSE004191R1
PFTL101B 2.0KN 3BSE004185R1
PFTL101B 5.0KN 3BSE004191R1
PFTL101BE 2.0KN 3BSE004214R1