sensors PFTL101A 0.5KN 3BSE004160R1

¥32,478.00

External connections:
• Excitation current to the load cells
• 2 or 4 analog inputs for load cell signals
• 4 analog outputs, voltage or current
• 8 digital inputs for control signals
• 8 digital outputs
• +24 V supply for external units, max 0.5 A
• Ethernet connection
• Service and multiple control units
• 2 serial interfaces of type RS-232 for
external displays, control, etc.

Model: PFTL101A 0.5KN 3BSE004160R1

Category: SKU: PFTL101A 0.5KN 3BSE004160R1 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

sensors PFTL101A 0.5KN 3BSE004160R1

sensors PFTL101A 0.5KN 3BSE004160R1

 

  • Error is proportional to the mutual coupling factor K0m
  • • The error increases with the parallel line earth current in relation to the relay current
  • • The relay underreaches when IEP is in phase with Iph + KN . IE . For a remote end terminal fault, this underreaching effect can be as high as 25%. The distance protection zone reaches vary with the switching state of the parallel line configuration.
  • We consider the three most common operation modes: 1. Case 1: Parallel line out of service and earthed at both ends 2. Case 2: Parallel line switched off and not earthed or earthed only at one line end 3. Case 3: Both lines in service. The reach of the distance protection zone 1 will be different depending on the operation condition of the parallel line.
  • Compensation of the mutual zero sequence impedance of parallel circuit can be achieved by appropriate selection of zero-sequence compensation factor KN when parallel line can be in service, out of service, or out of service and earthed at both ends.
  • Five zone distance protection, mho characteristic function (ZMHPDIS) can compensate for the influence of a zero sequence mutual coupling on the measurement at single phase-to-earth faults in the following two ways, by using:
  • • Different setting values that influence the earth -return compensation for different distance zones within the same group of setting parameters.
  • • Different groups of setting parameters for different operating conditions of a protected multi circuit line.

 

 

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

 

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

 

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

 

Related models:

PFSK113 7625013-S
PFSK130 3BSE002616R1
PFSK151 3BSE018876R1
PFSK152 3BSE018877R1
PFSK152 3BSE018877R2
PFSK160A 3BSE009514R1
PFSK162 3BSE015088R1
PFSK164 3BSE021180R1
PFTL101A 0.5KN 3BSE004160R1
PFTL101A 0.5KN 3BSE004172R1
PFTL101A 1.0KN 3BSE004166R1
PFTL101A 2.0KN 3BSE004172R1
PFTL101A 2.0KN 3BSE004191R1
PFTL101B 2.0KN 3BSE004185R1
PFTL101B 5.0KN 3BSE004191R1
PFTL101BE 2.0KN 3BSE004214R1