Analog input module 3BSE081637R1

¥25,478.00

External connections:
• Excitation current to the load cells
• 2 or 4 analog inputs for load cell signals
• 4 analog outputs, voltage or current
• 8 digital inputs for control signals
• 8 digital outputs
• +24 V supply for external units, max 0.5 A
• Ethernet connection
• Service and multiple control units
• 2 serial interfaces of type RS-232 for
external displays, control, etc.

Model: 3BSE081637R1

Category: SKU: 3BSE081637R1 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Analog input module 3BSE081637R1

Analog input module 3BSE081637R1

 

The remanence in the current transformer core can cause unwanted operations or minor additional time delays for some protection functions. As unwanted operations are not acceptable at all maximum remanence has been considered for fault cases critical for the security, for example, faults in reverse direction and external faults.

Because of the almost negligible risk of additional time delays and the non-existent risk of failure to operate the remanence have not been considered for the dependability cases.

The requirements below are therefore fully valid for all normal applications. It is difficult to give general recommendations for additional margins for remanence to avoid the minor risk of an additional time delay. They depend on the performance and economy requirements. When current transformers of low remanence type (for example, TPY, PR) are used, normally no additional margin is needed.

For current transformers of high remanence type (for example, P, PX, TPX) the small probability of fully asymmetrical faults, together with high remanence in the same direction as the flux generated by the fault, has to be kept in mind at the decision of an additional margin.

Fully asymmetrical fault current will be achieved when the fault occurs at approximately zero voltage (0°). Investigations have shown that 95% of the faults in the network will occur when the voltage is between 40° and 90°. In addition fully asymmetrical fault current will not exist in all phases at the same time.

 

 

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

 

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

 

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

 

Related models:

PFSK113 7625013-S
PFSK130 3BSE002616R1
PFSK151 3BSE018876R1
PFSK152 3BSE018877R1
PFSK152 3BSE018877R2
PFSK160A 3BSE009514R1
PFSK162 3BSE015088R1
PFSK164 3BSE021180R1
PFTL101A 0.5KN 3BSE004160R1
PFTL101A 0.5KN 3BSE004172R1
PFTL101A 1.0KN 3BSE004166R1
PFTL101A 2.0KN 3BSE004172R1
PFTL101A 2.0KN 3BSE004191R1
PFTL101B 2.0KN 3BSE004185R1
PFTL101B 5.0KN 3BSE004191R1
PFTL101BE 2.0KN 3BSE004214R1