PP845A 3BSE042235R2 operation panel

¥32,145.00

External connections:
• Excitation current to the load cells
• 2 or 4 analog inputs for load cell signals
• 4 analog outputs, voltage or current
• 8 digital inputs for control signals
• 8 digital outputs
• +24 V supply for external units, max 0.5 A
• Ethernet connection
• Service and multiple control units
• 2 serial interfaces of type RS-232 for
external displays, control, etc.

Model:PP845A 3BSE042235R2

Category: SKU: PP845A 3BSE042235R2 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

PP845A 3BSE042235R2 operation panel

PP845A 3BSE042235R2 operation panel

 

  1. The operator panel’s mounting clamps do not provide a secure grounding connection between the panel and the device cabinet.
  2. 2. Connect a 2.5 mm2 wire between the operator panel’s quick-connect plinth and the panel chassis.
  3. 3. Connect a 6 or 4 mm2 wire or grounding braid between the panel’s chassis and the closest grounding point on the door.
  4. 4. Connect a strong but short grounding braid between the door and the device cabinet.
  5. 5. Twist the cables onto the 24 V DC feed.
  6. 6. A ferrite core suppresses disturbances to the 24 V feed. 2 turns around the ferrite core provide 4 times the suppression of 1 turn. 3 turns around the ferrite core provide 9 times the suppression of 1 turn
  7. In some industrial units for Ethernet, the RJ45 contact’s shield is connected to the chassis via a capacitor.
  8. 2. The operator panel’s Ethernet shield is directly connected to the chassis. Check whether the other Ethernet unit has its shield directly grounded or grounded via a capacitor. In many cases, connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate. Hum or grounding loops can occur. Unshielded cabling may even result in fewer communication errors. A good solution may be to use a shielded Ethernet cable, but to connect the shield at one end only.
  9. 3. One option is to break the shield.
  10. 4. A more elegant method is to expand the shielded Ethernet cabling with a piece of unshielded Ethernet cable.
  11. 5. You can ground the shield via an external 0.1 uF/250 V plastic capacitor. This will connect the HF transients to the ground

 

 

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

 

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

 

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

 

Related models:

PP836 3BSE042237R1
PP836A 3BSE042237R2
PP845 3BSE042235R1
PP845A 3BSE042235R2
PP846 3BSE042238R1
PP846A 3BSE042238R2
PP865 3BSE042236R1
PP865A 3BSE042236R2
PP874 3BSE069271R2
PP875 3BSE092977R1
PP875H 3BSE092983R1
PP875M 3BSE092982R1