Examples of measuring values displayed:
Example 1:
Selected unit [N], Load cell nominal load 100 kN, Measured value 987654 N.
Value presented on display: 987600 N.
Example 2:
Selected unit [kN], Load cell nominal load 100 kN, Measured value 987654 N.
Value presented on display: 987.6 kN.
Examples of measuring values displayed together with the Set Decimals function:
Example 1:
Selected unit [pli], Load cell nominal load 1 kN, Measured value 46.5987 pli.
Set Decimals = 2
Value presented on display: 46.60 pli.
Example 2:
Selected unit [pli], Load cell nominal load 1 kN, Measured value 46.5987 pli.
Set Decimals = 0
Value presented on display: 47 pli.
4.7 Operator Menus
This section describes the operator menus. The updating time for displayed values is 500 ms.
Use up and to switch between menus.
The following menus are available when a standard roll (two load cells) is connected to the
tension electronics:
• WebTension
Shows the total web tension measured by load cell A and load cell B
• Tension A
Shows the part of web tension measured by load cell A
• Tension B
Shows the part of web tension measured by load cell B
• TensionDiff A-B
Shows the difference between Tension A and Tension B
4.7.1.2 Single Side A or Single Side B measurement (one load cell)
The following menu is shown when only one load cell (single side measurement) is connected
to the tension electronics:
• WebTension
Web Tension is displayed for single side measurement.
Web tension is the tension measured by the connected load cell multiplied by 2.
4.7.2 Error and Warning Messages
An ERROR is something that causes the tension electronics to function incorrectly.
A WARNING is something that might affect the accuracy of the measurement.
When a warning or an error occurs, a warning or an error message is displayed on the
Operator Panel and the “Status” indication turns from green to red.
When is pressed the message disappears from the display.
If the problem that activated the warning or error message has disappeared the
“Status” indication turns to green.
If the error or warning remains the “Status” indication is red. Use the to step to the last
menu, where you can read the error or warning message.