Description
3500/20 Due to the requirements for increased robustness in the TMR system, the TMR I/O
Module has a Velomitor interface that is different from the standard I/O Module’s
Velomitor interface. The effect of this difference is that the Velomitor signal input
to the I/O Module is 180 degrees out of phase from the correct Velomitor signal.
This inversion is compensated for in the TMR I/O Module. 3500/20 This means that when
you input a test signal using a signal generator or DC power supply the buffered
outputs on the front panel will be inverted in phase and will have a different DC
voltage than the input. This will not affect the actual vibration readings in the
Monitor.
brand | Product Name | Product model | Order No |
BENTLY | modular | 3500/20 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1806092-3929 |
3500/20 The general approach for testing OK limits is to input a DC voltage and adjust it
above the Upper OK limit and below the Lower OK limit. This will cause a not OK
condition and the OK Relay to change state (de-energize). The Upper and Lower
OK limits are displayed in the Verification screen on the test computer.
- Disconnect PWR, COM / A, and SIG / B field wiring from the channel
terminals on the I/O module.
- Connect test equipment and run software as described in Section 5.1.7.1
(Test Equipment and Software Setup – Velocity), page 177.
- Bypass all other configured channels.
- Adjust the power supply voltage to -7.00 Vdc.
- Press the RESET switch on the Rack Interface Module (RIM). Verify that the
monitor OK LED is on and 3500/20 that the Channel OK State line in the Channel
Status section of the Verification screen reads OK.
- Verify that the OK relay on the Rack Interface I/O Module indicates OK
(energized). See the 3500/20 Rack Interface Module Operation and
Maintenance Manual, part number 129768-01.
- Increase the power supply voltage (more negative) until the OK LED just
goes off (lower limit due to the inversion on the I/O Module). Verify that the
Channel OK State line on the Verification screen reads not OK and that the
OK Relay indicates not OK. Verify that the Lower OK limit voltage displayed
on the Verification screen is equal to or more negative than the following
value.
- 3500/20 Decrease the power supply voltage (less negative) to -7.00 Vdc.
- Press the RESET switch on the Rack Interface Module (RIM). Verify that the
OK LED comes back on and the OK relay energizes. Verify that the
Channel OK State line in the Channel Status section reads OK.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen