Description
GE General Electric Technical Specifications: IS200GGXIG1AED
Differential signals are measured on two wires which are separate, but not isolated from the
power supply. Differential inputs allow a greater degree of freedom in wiring commons and
grounds without affecting accuracy. There is a IS200GGXIG1AED limited voltage rating (see Common Mode)
between the signal level wires and the power supply wires. This limitation also applies to
voltage differences among additional I/O on the same supply. Differential inputs usually come
in groups sharing the supply common tie point. Some voltage outputs may have an external
return or remote sense which allows the load common or ground to be different than the supply
of the output module by a small voltage. Current loop signals are less susceptible to differences
in voltage between circuit IS200GGXIG1AED components (see compliance). Differential inputs permit series inputs
with current loops, since the signal can be offset from common. Do not confuse differential
inputs with isolated inputs; differential requires the common tie point reference for all inputs of
the group, usually either ground or the supply common.
brand | Product Name | Product model | Order No |
GE Fanuc | Module card | IS200GGXIG1AED | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
When a conductor is grounded in more than one place, ground potential differences can induce
currents producing voltage drops in the wire. If the IS200GGXIG1AED conductor is also used to carry an analog
signal, these voltage drops produce an accuracy error or noisy values. If a single point ground is
used, the voltage difference between locations may still appear in series with the desired signal.
This is overcome by using differential or isolated inputs and running a separate return from the
remote source. This preserves the integrity of the signal, and the ground voltages appear as
common mode voltage at the receiving end.
Isolated inputs are usually two-wire and are dialectrically insulated from supplies and ground.
Sometimes additional connections are provided for excitation of transducers such as RTDs, but
these signals are not shared with IS200GGXIG1AED other I/O points. Isolated modules allow high voltages to exist
between I/O devices and the PLC. Do not confuse isolated inputs with the isolation between
groups of analog circuits, or isolation from other components of the system, such as logic or
power supplies.
This is the actual signal across the signal wires of differential or isolated I/O. This may also
include unwanted noise such as power line frequency pickup.
Single-ended circuits have the signal measured relative to a common connection, usually the
power supply. Other analog I/O signals typically share this common. Single-ended circuits
require fewest terminal points, giving the highest density and lowest price, but at the cost of
more restrictive wiring and errors due to voltage drops and currents in the common connections.
Single-ended circuit connections are most similar to the wiring of discrete modules.
The term unipolar means, literally, one pole. Unipolar signals or ranges do not change polarity
during normal operation; for example 0 to 10 volts, or 4mA to 20mA. Reversed connection to a
unipolar input will produce minimum value and, if diagnostics are available, underrange or
open wire faults.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de
The maximum number of 8-Channel Analog Current/Voltage Output modules that can be installed
in a system are:
4 in a system using CPU Models 311, 313, or 323
8 in a system using CPU Model 331
32 in a system using CPU Models 340 and 341
64 in a system using CPU Models 350 – 364
Other Configuration Considerations
When planning the module configuration for your application you must also consider the load
capacity of the installed power supply and the total load requirements of all modules that are
installed in the baseplate.
Refer to Chapter 1 in this manual for details on power supply, baseplate, and module load
requirements. The following table lists the specifications for this module. Note that test conditions,
unless otherwise noted, are: VUSER = 24 VDC at an ambient temperature of 25 C (77 F)
livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen