Description
GE General Electric Technical Specifications: IS200ICBDH1BAA
To store setpoints from the front panel keypad, IS200ICBDH1BAA terminals C1 and C2 (access terminals) must be shorted (a key switch may
be used for security). There is also a setpoint passcode feature that can restrict setpoint access from the keypad and com
munication ports. If activated, the passcode must be entered before changing the setpoint values. A passcode of 0 turns off
the passcode feature and only the access jumper is required to IS200ICBDH1BAA change setpoints. If no setpoint changes are made for 30
minutes, access to setpoint values will be restricted until the passcode is entered again. To prevent setpoint access before
the 30 minutes expiry, the unit may be turned off and back on, the access jumper may be removed, or the SETPOINT
ACCESS setpoint may be changed to Restricted. The passcode for the front panel keypad cannot be entered until terminals
C1 and C2 are shorted. The SETPOINT ACCESS indicator will be on if setpoint access is enabled for the front panel key
pad.
brand | Product Name | Product model | Order No |
GE Fanuc | Module card | IS200ICBDH1BAA | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
A IS200ICBDH1BAA alarm feature may be assigned to operate any combination of four output relays: R5 Alarm, R4 Auxiliary, R3 Auxil
iary, and R2 Auxiliary. When an Alarm becomes active, the appropriate LED (indicator) on the 489 faceplate will illuminate
when an output relay(s) has operated. Each alarm feature may be programmed as latched or unlatched. Once a latched
alarm feature becomes active, the reset key must be pressed to reset that alarm. If the condition that has caused the alarm
is still present (for example, hot RTD) the Alarm relay(s) will not reset until the condition is no longer present. If on the other
hand, an unlatched alarm feature becomes active, that alarm will reset itself (and associated output relay(s)) as soon as the
condition that caused the alarm ceases. As soon as an alarm occurs, the alarms messages are updated to reflect the alarm
and the IS200ICBDH1BAA display defaults to that message. Since it may not be desirable to log all alarms as events, each alarm feature
may be programmed to log as an event or not. If an alarm is programmed to log as an event, when it becomes active, it is
automatically logged as a date and time stamped event.
- c) CONTROL
A 489 control feature may be assigned to operate any combination of five output relays: R5 Alarm, R4 Auxiliary, R3 Auxil
iary, and R2 Auxiliary, and R1 Trip. The combination of relays available for each function is determined by the suitability of
each relay for that particular function. The appropriate LED (indicator) on the 489 faceplate will illuminate when an output
relay(s) has been operated by a control function. Since it may not be desirable to log all control function as events, each
control feature may be programmed to log as an event or not. If a control feature is programmed to log as an event, each
control relay event is automatically logged with a date and time stamp.
4.1.2 RELAY ASSIGNMENT PRACTICES
There are six output relays. Five of the relays are always non-failsafe, the other (Service) is failsafe and dedicated to
annunciate internal 489 faults (these faults include setpoint corruption, failed hardware components, loss of control power,
etc.). The five remaining relays may be programmed for different types of features depending on what is required. One of
the relays, R1 Trip, is intended to be used as a trip relay wired to the unit trip breaker. Another relay, R5 Alarm, is intended
to be used as the main alarm relay. The three remaining relays, R2 Auxiliary, R3 Auxiliary, and R4 Auxiliary, are intended
for special requirements.
When assigning features to R2, R3, and R4 it is a good idea to decide early on what is required since features that may be
assigned may conflict. For example, if R2 is to be dedicated as a relay for sequential tripping, it cannot also be used to
annunciate a specific alarm condition.
In order to ensure that conflicts in relay assignments do not occur, several precautions have been taken. All trips default to
the R1 TRIP output relay and all alarms default to the R5 Alarm relay. It is recommended that relay assignments be
reviewed once all the setpoints have been programmed.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de
The maximum number of 8-Channel Analog Current/Voltage Output modules that can be installed
in a system are:
4 in a system using CPU Models 311, 313, or 323
8 in a system using CPU Model 331
32 in a system using CPU Models 340 and 341
64 in a system using CPU Models 350 – 364
Other Configuration Considerations
When planning the module configuration for your application you must also consider the load
capacity of the installed power supply and the total load requirements of all modules that are
installed in the baseplate.
Refer to Chapter 1 in this manual for details on power supply, baseplate, and module load
requirements. The following table lists the specifications for this module. Note that test conditions,
unless otherwise noted, are: VUSER = 24 VDC at an ambient temperature of 25 C (77 F)
livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen