GE General Electric Technical Specifications: IS200VVIBH1C
IS200VVIBH1C Indications and Operations are as outlined under Phase Time Overcurrent 1.
Blocking From Logic Inputs:
- Decrease the Va frequency at a rate to cause a pickup.
- Assert a logic input to provide a “Block Frequency Decay”. The PICKUP indicator should immediately go
out.
- Repeat steps 1 and 2 for logic input “Block 1 TRIP Relay” as required.
IS200VVIBH1C Timing:
- Connect the Stop Trigger.
- Preset the ramp-rate to a minimum of 110% of the pickup and reset the timer.
- Inject the preset voltage into the Va bus voltage input and note the measured delay time. Reset the timer.
- Repeat step 3 four more times and obtain an average of the time intervals.
- Disconnect the Stop Trigger.
brand | Product Name | Product model | Order No |
GE Fanuc | Module card | IS200VVIBH1C | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
Test Connections per Figure 17–1: RELAY TEST WIRING – WYE CONNECTION or Figure 17–2: RELAY
IS200VVIBH1C TEST WIRING – DELTA CONNECTION on page 17–4.
- Ensure the wiring to the circuit breaker trip and close circuits is complete.
- Energize the breaker trip and close circuits and close the breaker.
- Carefully disconnect a wire to open the trip circuit.
- Set a test current level 3% above the Breaker Failure Current setpoint and inject current into a phase cur
rent input. (All O/C protection features are Disabled.)
- Assert a Trip logic input, which cannot be performed by the breaker. After a delay the element should gen
erate an output. (The delay time can be checked in the Event Recorder.) Turn the current off and Reset the
relay.
- Reduce the current magnitude to 3% below the Breaker Failure Current setpoint and inject current into a
phase current input. Assert a Trip logic input, which cannot be performed by the breaker. The element
should not generate an output.
Indications and Operations are as outlined under Phase Time Overcurrent 1. This element has no Trip
function.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de
livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen