Description
Single PBA
To install the PBA cables for a nonredundant configuration
(one PBA):
- Install the redundant processor bus adapter cable.
NOTE: Refer to Section 8 and Appendix B to determine the type and length of
the cable.
- Position the end socket connector on the PBA bracket so
that the pins of the cable are facing outward.
- Install a terminator to the end socket connector on the
redundant processor bus adapter cable.
NOTE: The end socket connector is keyed, but the terminator is not. The termi
nator can be installed in any direction.
- Insert the next keyed connector on the redundant proces
sor bus adapter cable into the P1 connector on the PBA with
the terminator mounted to it.
- The next keyed connector on the cable is used only for
redundant installations and has no purpose in single PBA
installations. It can be left hanging.
- Attach the final cable connector to the I/O column after
the PBAs have been mounted. Continue to Mounting in this
section to mount the PBA.
NOTE: The TU cable for the direct station link can be installed at any time after
the PBA is installed. Refer to Appendix B for more information.
Before installing a controller:
- Check all controller dipswitch and jumper settings (normal
and special operation).
- Verify that the PBA if required, is attached to the proper
slot on the MMU backplane.
NOTE: Controllers can be installed and removed under power. When doing so,
the status LED will turn red momentarily and then turn green. If it does not,
refer to Section 5 for troubleshooting information.
To install a controller:
- Slide the controller into its mounting slot while guiding the
top and bottom edges of the controller along the top and bot
tom rails of its assigned slot in the MMU.
Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
Stock products of the same series:
DO880 3BSE028602R1 |
DATX130 3ASC25H214 |
DI810-EA 3BSE008508R2 |
CMA 132 3DDE300412 |
CTB810 HN800/CW800 |
DAPC 100 3ASC25H203 |
DAPU100 3ASC25H204 |
CPM810 |
CI532V03 3BSE003828R1 |
CI627A 3BSE017457R1 |
CP450T 1SBP260188R1001 |
CS513 3BSE000435R1 IEEE 802.3 |
CI856K01 3BSE026055R1 |
CP800 HPC800 |
CP410M 1SBP260181R1001 |
CI853K01 3BSE018103R1 |
CI854AK01-EA PRC3BSE030220R2 |
CI830 3BSE013252R1 |
B4LE 1KHL015045P0001 |
BB510 3BSE001693R2 |
BC810 3BSE031154R1 |
ASFC-01C 64649540 |
AINT-02C 64715810 |
AGPS21C GDR AGPS-21C |
APOW-01C 64605666 |