Description

Using the Redundancy Link Module RLM 01 will do the conversion of one simple, non-redundant Profibus line into two reciprocally redundant lines.
You can position the Redundancy Link Module RLM 01 directly
after a Profibus module (master), before a bus segment with
several slaves or before an individual slave. PROFIBUS stations with redundant couplers can be directly connected to the
PROFIBUS set redundant by RLM 01. Stations with only one interface can be optionally assigned to the one or other line.
For technical description dates of the Redundancy Link Module
RLM 01 see document 3BDD011600R0201.
An alternative solution to the Profibus line redundancy is to use
a Fiber Optic Ring, for example with the OZD Profi 12M module

You can achieve both; controller redundancy and Profibus line
redundancy by using two AC 800F with one RLM01 each. This
topology combines the advantages of controller redundancy
with the one of line redundancy as described in the above
paragraphs.

The basic unit, PM 802F and respectively PM803F, cyclically
scans signals from the fieldbus sensors via the corresponding
fieldbus modules, processes these signals according the application programs installed by the user and sends appropriate
signals to the fieldbus actuators via the fieldbus modules.
Controller redundancy can be achieved by installing two
AC 800F. To ensure quick and smooth takeover by the secondary AC 800F in case the primary AC 800F fails, a dedicated
redundancy communications link through the second Ethernet
module makes sure that both AC 800F are always synchronized. All inputs and outputs are designed to support redundant
operation.
Data communication between AC 800F, process and operator
stations runs over the Ethernet system bus on the first Ethernet
module. Data exchange with the engineering station is also carried via the system bus. Engineering station communications
can involve new or updated configuration files being
downloaded to the process stations, or information about the
connected modules being reported back. When fieldbus modules are installed or exchanged, the required configuration information is automatically updated.
Configuration and real-time process data is stored in RAM. To
safeguard this data in case of power loss, the RAM power is
backed up with batteries located either on the Ethernet modules
or on battery modules.
The PM 803F has more memory than the PM 802F and is
therefor capable to handle larger projects. Due to increased
memory size and different technology the buffering times were
reduced.

 

Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

Stock products of the same series:

EI 813F 3BDH000022R1
DSTA 002A 3BSE015196R1
DSTA 145 57120001-HP
DSTA 131 57120001-CV
087147-002 ABB HKQCS
G3LA 1KHW000623R0101
G1LB 1KHW000601R0002
FS300R12KE3 AGDR-72C
FI 830F 3BDH000032R1
FAU810 C10-12010
NSD570
G3LR 1KHW000628R0101
G3LH 1KHW000640R0001
G3LC 1KHW000621R0001
DSDI 115 57160001-NV
HIER466587R0200
HIEE405246R0002 UNS 0867A-P V2
HPC800
DSAO 120A 3BSE018293R1
DSAX 110A 3BSE018291R1
DSBC 172 57310001-KD
DSBC 176 3BSE019216R1
DSAI 130 57120001-P
DSAI 130D 3BSE003127R1
DSAI 146 3BSE007949R1
DO810 3BSE008510R1
DSAI 133A 3BSE018290R1
DO880 3BSE028602R1
DATX130 3ASC25H214
DI810-EA 3BSE008508R2
CMA 132 3DDE300412
CTB810 HN800/CW800
DAPC 100 3ASC25H203
DAPU100 3ASC25H204
CPM810
CI532V03 3BSE003828R1
CI627A 3BSE017457R1
CP450T 1SBP260188R1001
CS513 3BSE000435R1 IEEE 802.3
CI856K01 3BSE026055R1
CP800 HPC800