Description
Provides configuration write access to the 3500 rack. If the password entered in
this field does not match the password entered in the Rack Configuration Software
“Download” screen, the 3500 rack will not accept new configurations. This
password is also required to change setpoints in the 3500 rack from the Operator
Display Software. This password is stored in non-volatile memory in the Rack
Interface Module.
Front Port
The port on the front of the Rack Interface Module labelled CONFIGURATION
PORT that is primarily used to configure the 3500 rack with a personal computer.
This port may also be used to retrieve machinery data for display using the Data
Acquisition/DDE Server Software and the Operator Display Software. This port
supports RS-232 only and provides access to only one rack.
External Modem
The following external modems are directly supported by the Rack Interface
Module:
None
Hayes Ultra 9600
Hayes Optima 9600
Motorola FasTalkII 9600
Custom
Initialization String
The command that sets up and starts the modem. If you select a modem from
the list, the default initialization string will be displayed in this field. If you select
Custom, enter an initialization string from information found in the modem’s
documentation.
Byte Timeout
The number of byte times for which the communication line must be idle before
a communication is considered complete. One byte time is a function of the
baud rate selected. The range of values is 3 to 255.
brand | Product Name | Product model | Order No |
BENTLY | modular | 126599-01 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
Static Data Considerations
Each static data port can access six monitor slots in the 3500 rack. Each monitor
slot in the 3500 rack is limited to 32 PPLs.
Dynamic Signal Option
Identifies which monitors provide dynamic data to the DYNAMIC connectors on the
Data Manager I/O Module. This field defines how the 3500 rack will provide
machinery data to the Communication Processors (TDIX or DDIX).
The following table shows the different options that are available. Keep the
following in mind:
ï Dynamic Port 2 is always assigned to slots 8 through 13.
ï If a slot contains something other than a monitor, then no data for that slot
is returned.
ï No data can be returned from the modules installed in slots 14 and 15.
The following Agency Approvals are available for the 3500 rack:
None
CSA-NRTL/C
CE Approval
Select this box if the CE mark is applicable to the rackís installation.
Rack Mounting Option
Select the type of 3500 rack that is or will be installed. Refer to the 3500
Monitoring System Rack Installation and Maintenance Manual for a description of
the various mounting options.
Power Supply
The following power supplies can be installed in the 3500 rack:
Upper Position in Slot
Lower Position in Slot
No Power Supply
AC High Voltage
AC Low Voltage
DC High Voltage
No Power Supply
AC High Voltage
AC Low Voltage
DC High Voltage