Description
Install the upgrade firmware IC into the PWA. Be sure to match the notched end
of the IC to the notched end of the socket. Ensure that the IC is firmly seated in
the socket.
Top Shield Replacement
Replace the top shield. Position the notch on the top shield so that it is at the top
left corner of the module as shown in the diagram under ìTop Shield Removalî.
Align the holes in the top shield with the standoffs and press down around each
standoff until they snap in place.
brand | Product Name | Product model | Order No |
BENTLY | modular | 133300-01 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
This section describes how to troubleshoot a problem with the Rack Interface
Module or the I/O modules by using the information provided by the verification
screen, the LEDs, the System Event List, and the Alarm Event List. You can
display the verification screen and the two event lists by using the Rack
Configuration Software.
Verification
To perform the Rack Interface Module’s verification:
- Connect a computer running the Rack Configuration Software to the 3500
rack (if needed).
- Select Utilities from the main screen of the Rack Configuration Software.
- Select Verification from the Utilities menu.
- Select the Rack Interface Module and select the channel you want to verify.
- Press the Verify button.
- Select the Front Port or the Rear Port to get the status.
- The Module OK State will show the Rack Interface Module’s status and the
Channel OK State will show the channel’s status.
Sequence Number: The number of the event in the System Event List (for
example 123).
Event Information: The name of the event (for example Device Not
Communicating).
Event Number: Identifies a specific event.
Class: Used to display the severity of the event.
Severe/Fatal Event
Potential Problem Event
Typical Logged Event
Reserved
Event Date: The date the event occurred.
Event Time: The time the event occurred.
Event Specific: Provides additional information for the events that use
this field.
Slot: Identifies the module that the event is associated with.
If a half-height module is installed in the upper slot or a
full-height module is installed, the field will be 0 to 15.
If a half-height module is installed in the lower slot,
then the field will be 0L to 15L. For example, the
module is installed in the lower position of slot 5 (5L)
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen