Description

Pass Main Board +15V-AB (Pass Main Board +15V – upper and lower

Power Supplies)

Event Number: 111

Event Classification: Severe / Fatal Event

Action: Verify that noise from the power source is not causing the

problem. If the problem is not caused by noise, check to see if

one of the following components is faulty:

ï Rack Interface Module

ï Power Supply installed in the lower slot

ï Power Supply installed in the upper slot

Fail Main Board -24V-A (Fail Main Board -24V – upper Power Supply)

Event Number: 112

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the

problem. If the problem is not caused by noise, check to see if

one of the following components is faulty:

ï Rack Interface Module

ï Power Supply installed in the upper slot

Pass Main Board -24V-A (Pass Main Board -24V – upper Power Supply)

Event Number: 113

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the

problem. If the problem is not caused by noise, check to see if

one of the following components is faulty:

ï Rack Interface Module

ï Power Supply installed in the upper slot

Fail Main Board -24V-B (Fail Main Board -24V -upper and lower Power

Supply)

Event Number: 114

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the

problem. If the problem is not caused by noise, check to see if

one of the following components is faulty:

ï Rack Interface Module

ï Power Supply installed in the lower slot

Pass Main Board -24V-B (Pass Main Board -24V – lower Power Supply)

Event Number: 115

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the

problem. If the problem is not caused by noise, check to see if

one of the following components is faulty:

ï Rack Interface Module

ï Power Supply installed in the lower slot

brand Product Name Product model Order No
BENTLY modular 133388-02 3500/50 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

Fail Main Board -24V-AB (Fail Main Board -24V – upper and lower Power

Supplies)

Event Number: 116

Event Classification: Severe / Fatal Event

Action: Verify that noise from the power source is not causing the

problem. If the problem is not caused by noise, check to see if

one of the following components is faulty:

ï Rack Interface Module

ï Power Supply installed in the lower slot

ï Power Supply installed in the upper slot

Pass Main Board -24V-AB (Pass Main Board -24V – upper and lower

Power Supplies)

Event Number: 117

Event Classification: Severe / Fatal Event

Action: Verify that noise from the power source is not causing the

problem. If the problem is not caused by noise, check to see if

one of the following components is faulty:

ï Rack Interface Module

ï Power Supply installed in the lower slot

ï Power Supply installed in the upper slot

Device Configured

Event Number: 300

Event Classification: Typical Logged Event

Action: No action required.

Configuration Failure

Event Number: 301

Event Classification: Severe/Fatal Event

Action: Replace the Rack Interface Module immediately.

Configuration Failure

Event Number: 301

Event Classification: Potential Problem

Action: Download a new configuration to the Rack Interface Module. If the

problem still exists, replace the Rack Interface Module as soon as

possible.

Module Entered Cfg Mode (Module Entered Configuration Mode)

Event Number: 302

Event Classification: Typical Logged Event

Action: No action required.