Description
All the Alert/Alarm 1 setpoints are provided first, followed by the configured
Danger/Alarm 2 setpoints.
Example 1:
A Tachometer configured for Rotor Speed with the Danger/Alarm 2 Over
Speed and the Danger/Alarm 2 Under Speed setpoints selected.
Alert/Alarm 1 setpoints:
setpoints 1 through 4
Danger/Alarm 2 setpoints:
setpoint 5 is Over Speed (Danger/Alarm 2)
setpoint 6 is Under Speed (Danger/Alarm 2)
Example 2:
A Tachometer configured for Zero Speed with the Danger/Alarm 2 Zero
Speed Under setpoint selected.
Alert/Alarm 1 setpoints:
setpoints 1 through 3
Danger/Alarm 2 setpoint:
setpoint 4 is Zero Speed Under (Danger)
The alarming hysteresis for all setpoints is 10 RPM (with the exception of
Zero Speed which is configurable). When a channel exceeds an alarm
setpoint, it must fall back below the setpoint less the hysteresis before it
can go out of alarm. For example, consider a channel with an alarm
setpoint at 4250 RPM as illustrated. The channel input must fall below
4240 RPM (4250 – 10) before the channel is out of alarm.
brand | Product Name | Product model | Order No |
BENTLY | modular | 135489-02 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
The Tachometer Monitor supports four module software switches and four
channel software switches. These switches let you temporarily bypass,
inhibit, or invoke monitor and channel functions. Set these switches on the
Software Switches screen under the Utilities Option on the main screen of
the Rack Configuration Software.
A switch that allows the monitor to be configured. To configure the
monitor, enable ( ) this switch and set the key switch on the front of the
Rack Interface Module in the PROGRAM position. When downloading a
configuration from the Rack Configuration Software, this switch will
automatically be enabled and disabled by the Rack Configuration
Software. If the connection to the rack is lost during the configuration
process, use this switch to remove the module from Configuration Mode.
Monitor Alarm Bypass
When this switch is enabled, the monitor does not perform alarming
functions. All proportional values are still provided.
Manual Keyphasor Threshold Adjust
Used when adjusting the manual threshold. This switch will automatically
be enabled and disabled when the Adjust button on the Tachometer
Monitor Options screen is pressed. When in this mode the Tachometer
Module will operate with a temporary Manual Threshold supplied by the
Rack Configuration Software. Proportional values may go invalid,
alarming will be bypassed, and Conditioned Keyphasor will not be
supplied while the Manual Threshold is being adjusted.
Zero Speed Enable
The Zero Speed Enable switch is a permissive switch that allows alarms
to occur for Zero Speed and Reverse Rotation. When the switch is
enabled, these alarms will occur when the alarm condition is present. If
the switch is not enabled, the alarms will be bypassed even when the
alarm condition is present.