Bently Nevada 145988-02 3500/65 Monitor detection

Product name:Bently Nevada 145988-02 3500/65

Product model:145988-02 3500/65

Quantity: inventory

Warranty: We provide warranty service for 145988-02 3500/65

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

You can use software
configuration to set Alert and
Danger setpoints for the value
measured by the monitor. Alarms
are adjustable from 0 to 100% of
full-scale for each measured
value. The exception is when the
full-scale range exceeds the range
of the sensor. In this case,
software will limit the setpoint to
the range of the sensor. Accuracy
of alarms are to within 0.13% of the
desired value. The 3500/65 16-
channel temperature monitor has
both under- and over-alarm
setpoints.
Alarm
Time
Delays
You can use software to program
alarm delays as follows:
Alert
Delay
From 1 to 60 seconds in 1-second
increments.
Danger
Delay
From 1 to 60 seconds in 0.5-
second increments or set to the
minimum alarm delay of 225 mS.
Proportional Values
Proportional values are temperature
measurements used to monitor the machine.
The 16-channel temperature monitor returns
temperature proportional values.
Environmental Limits
Operating
Temperature:
-30°C to +65°C (-22°F to
+150°F)
Storage
Temperature:
-40°C to +85°C (-40°F to
+185°F)

brand Product Name Product model Order No
BENTLY modular 145988-02 3500/65 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

The two channel 3500/53 Overspeed Detection System provides overspeed

protection as part of the 3500 Machinery Management and Protection System.

The two channel Overspeed Detection System includes the 3500 rack, 3500

Power Supplies, Rack Interface Module, and two separate Overspeed Detection

Modules. Two separate transducer inputs are required. The 3500/53 Modules

can be installed in any slot to the right of the Rack Interface Module (2-15) but

must be installed adjacent to each other in the group of two. Only one

Overspeed Detection System may be installed in each 3500 rack (unless an

appropriate Custom Products modification is installed on the system backplane).

The 3500/53 Overspeed Detection System may be installed in a 3500 rack that

includes other 3500 monitoring functions.

The Two Channel Overspeed Detection System provides two channels of

independent speed monitoring. The Two Channel Overspeed Detection System

provides 1 out of 2 voting on alarming.

When used as a Safety Shutdown System for the purposes of Functional Safety,

the 3500/53 Overspeed Detection System, as certified by TUV Rheinland, is

restricted in its available configurations. Additionally, the certificate is contingent

upon certain requirements of use. Reference the limitations stated below.

Configuration Limitations and Requirements

  • Installation performed by Bently Nevada personnel
  • Discrete configuration only (each monitor channel has dedicated transducers)
  • Redundant power supplies are required
  • 3 module systems only
  • All 3 monitors in the system must be located adjacent to one another
  • Inter-Module Comparison enabled
  • OR “Not OK” Voting enabled
  • Percentage Comparison enabled
  • CE Mark required
  • Agency Approvals required
  • Only 3300XL ProximitorsÒ and certain Magnetic Pick-ups are allowed
  • Only accepted Proximity Probes allowed (Reference current FS Mark certificate for the

complete list of approved transducers.)

Reference current FS Mark certificate for a list of intrinsically safe barriers allowed for use

in a Functional Safety System

Only Normally Energized relays are allowed for use

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required