3500/05-02-04-01-00-00 Bently Nevada Modbus input data

¥1,800.00

Product name:Bently Nevada 3500/05-02-04-01-00-00

Product model:3500/05-02-04-01-00-00

The maximum number of input registers read in a single query is

limited to 114 registers by the Communication Gateway I/O Module (Modbus)

and may be limited by the DCS controller. Refer to the appropriate DCS controller manual for more information.

 

60 in stock

Category: SKU: 3500/05-02-04-01-00-00
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

3500/05-02-04-01-00-00 The data fields and their meanings are described in the following paragraphs.

The slave address and the CRC check have the same format and meaning as

described in earlier sections.

Start Address

Start Address is the 16-bit Modbus holding register address corresponding to the

starting value. The higher order byte is transmitted first followed by the lower

order byte. The allowed ranges are 0 to 6999 (Zero referenced). Any address

outside this range will result in the exception response “ILLEGAL ADDRESS”.

See page 37 for the mapping of the Modicon PC Registers to the Communication

Gateway I/O Module (Modbus) data.

Number of Registers

This 16-bit field is the number of values to be obtained beginning at the “Start

Address”.

brand Product Name Product model Order No
BENTLY modular 3500/05-02-04-01-00-00 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

The format of the response to Read Holding Registers is shown below. The

response includes the slave address, function code, number of bytes of data

being sent, and the CRC check. The contents of the registers requested are two

bytes each: the first byte is the high order and the second byte is the lower order.

Note that the Byte Count is the number of bytes in the data portion of the

response or two times the number of registers.

The data fields and their meanings are described in the following paragraphs.

The slave address and the CRC check have the same format and meaning as

described in earlier sections.

Start Address

Start address is the 16-bit Modbus input data register address corresponding to

the first register. The higher order byte is transmitted first followed by the lower

order byte. The allowed ranges are 0 to 956 (Zero referenced). Any address

outside this range will result in the exception response “ILLEGAL ADDRESS”.

See page 37 for the mapping of the Modicon PC Registers to the Communication

Gateway I/O Module (Modbus) data.

Number of Registers

This 16-bit field is the number of values to be obtained beginning at the “Start

Address”. The maximum number of input registers read in a single query is

limited to 125 registers by the Communication Gateway I/O Module and may be

limited by the DCS controller. Refer to the appropriate DCS controller manual for

more information.

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required