3500/15 133292-01 Bently Nevada Communication Gateway I/O Template

¥1,800.00

Product name:Bently Nevada 3500/15 133292-01

Product model:3500/15 133292-01

Install the U5 upgrade. Place part number 137495-01 into the top socket

on the PWA. Be sure that the notched end of the IC is matched to the notched

end of the socket. Ensure that the IC is firmly seated in the socket.

60 in stock

Category: SKU: 3500/15 133292-01
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

3500/15 133292-01 nstall the upgrade firmware ICs into the PWA.

Step 2. Install the U6 upgrade. Place part number 137494-01 into the bottom

socket on the PWA. Be sure that the notched end of the IC is matched to the

notched end of the socket. Ensure that the IC is firmly seated in the socket.

Top Shield Replacement

Replace the top shield. Be sure that the notch on the top shield is positioned at

the top left corner of the module as shown in the diagram under “Top Shield

Removal”. Align the holes in the top shield with the standoffs and press down

around each standoff until they snap in place.

This section describes how to troubleshoot a problem with the Communication

Gateway Module or the I/O module by using the information provided by the self

test, the LEDs, the System Event List, and the Alarm Event.

Self-test

To perform the Communication Gateway Module self-test:

Connect a computer running the Rack Configuration Software to the 3500 rack (if

needed).

Select Utilities from the main screen of the Rack Configuration Software.

Select System Events/Module Self-test from the Utilities menu.

Press the Module Self-test button on the System Events screen.

brand Product Name Product model Order No
BENTLY modular 3500/15 133292-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

Select the slot that contains the Communication Gateway Module and press the

OK button. The Communication Gateway Module will perform a full self-test

and the System Events screen will be displayed. The list will not contain the

results of the self-test.

Wait 30 seconds for the module to run a full self-test.

Press the Latest Events button. The System Events screen will be updated to

include the results of the self-test.

Verify that the Communication Gateway Module passed the self-test. If the

module failed the self-test, refer to Section 7.3

Event Date: The date the event occurred.

Event Time: The time the event occurred.

Event Specific: Provides additional information for the events that use

this field.

Slot: Identifies the module that the event is associated with.

If a half-height module is installed in the upper slot or a

full-height module is installed, the field will be 0 to 15.

If a half-height module is installed in the lower slot,

then the field will be 0L to 15L. For example, a module

installed in the lower position of slot 5 would be 5L.

The following System Event List Messages are associated with the

Communication Gateway Module and are listed in numerical order. If an event

marked with a star (*) occurs, both ports on the Communication Gateway I/O

Module will stop communicating. If you are unable to solve any problems,

contact your nearest Bently Nevada office.

Flash Memory Failure

Event Number: 11

Event Classification: Potential Problem

Action: Replace the Communication Gateway Module as soon as

possible.

Internal Network Failure

Event Number: 30

Event Classification: Severe/Fatal Event

Action: Replace the Communication Gateway Module immediately.

Device Not Communicating

Event Number: 32

Event Classification: Potential Problem

Action: Check to see if one of the following components is faulty:

the Communication Gateway Module

the rack backplane

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required