Description
3500/42 125972-02 Fail Main Board -VA-AB (Fail Main Board -VA – upper and lower Power
Supplies)
Event Number: 140
Event Classification: Severe/Fatal Event
Action:
3500/42 125972-02 Verify that noise from the power source is not causing the problem.
If the problem is not caused by noise, check to see if one of the
following components is faulty:
• the Monitor Module
• the Power Supply installed in the upper slot
• the Power Supply installed in the lower slot
Monitor Module will stop alarming.
Pass Main Board -VA-AB (Pass Main Board -VA – upper and lower Power
Supplies)
Event Number: 141
Event Classification: Severe/Fatal Event
Action:
Verify that noise from the power source is not causing the problem.
If the problem is not caused by noise, check to see if one of the
following components is faulty:
• the Monitor Module
• the Power Supply installed in the upper slot
• the Power Supply installed in the lower slot
Device Configured
Event Number: 300
Event Classification: Typical Logged Event
Action:
No action required.
brand | Product Name | Product model | Order No |
BENTLY | modular | 3500/42 125972-02 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
Configuration Failure
Event Number: 301
Event Classification: Potential Problem or Severe/Fatal Event
Action:
Download a new configuration to the Monitor Module. If the
problem still exists, replace the Monitor Module immediately.
Monitor Module will stop alarming.
* Module Entered Cfg Mode (Module Entered Configuration Mode)
Event Number: 302
Event Classification: Typical Logged Event
Action:
No action required.
Monitor Module will stop alarming.
Software Switches Reset
Event Number: 305
Event Classification: Potential Problem
Action:
Download the software switches to the Monitor Module. If the
software switches are not correct, replace the Monitor Module as
soon as possible.
Monitor TMR PPL Failed (Monitor TMR Proportional Value Failed)
Event Number: 310
Event Classification: Potential Problem
Action:
Verify that the sensor is properly installed. If the sensor is properly
installed, check to see if one of the following components is faulty:
• the sensor
• the I/O Module
• the 3500/63 Main Module
Monitor TMR PPL Passed (Monitor TMR Proportional Value Passed)
Event Number: 311
Event Classification: Potential Problem
Action:
Verify that the sensor is properly installed. If the sensor is properly
installed, check to see if one of the following components is faulty:
• the Sensor
• the I/O Module
• the 3500/63 Main Module
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required