07KT98 GJR5253100R4278 ABB Controller module motor card inventory

Numer modelu: 07KT98 GJR5253100R4278
Manufacturer: ABB
Quantity:ten
Serial ports: 6
Network ports: 8
Port isolation: 500 VDC
Weight : 3.18 Kg
Shipping Weight : 4.5 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

07KT98 GJR5253100R4278 Electrical parameters
Accuracy: ± 1mm in water
Repeatability: ± 0.5mm in water
Frequency: 1.5MHZ
Power supply voltage: 12-36VDC
Relay: 25mA
Power consumption: not immersed in liquid state: 5mA Immersed in liquid state: 19mA
Relay level: 60VDC/ VAC@1A
FET level: 36VDC@100mA
Switch output: can choose NO or NC status
Temperature range: F -40~194 C -40~90
Pressure level: When the pressure is 150psi (10bar) at 25 ℃, there is a decrease of 1.667pdi (113bar) per degree Celsius above 25 ℃
Probe material: PP or PEA

 

Utilization categories
The utilization category of a circuit-breaker shall be stated with reference to
whether or not it is specifically intended for selectivity by means of an intentional
time delay with respect to other circuit-breakers in series on the load side, under
short-circuit conditions (Table 4 IEC 60947-2).
Category A – Circuit-breakers not specifically intended for selectivity under
short-circuit conditions with respect to other short-circuit protective devices in
series on the load side, i.e. without a short-time withstand current rating.
Category B – Circuit-breakers specifically intended for selectivity under shortcircuit conditions with respect to other short-circuit protective devices in series
on the load side, i.e. with and intentional short-time delay provided for selectivity under short-circuit conditions. Such circuit-breakers have a short-time
withstand current rating.
A circuit-breaker is classified in category B if its Icw is higher than (Table 3 IEC
60947-2):
12·In or 5 kA, whichever is the greater for In ≤ 2500A
30 kA for In > 2500A
Electrical and mechanical durability
Mechanical durability
The mechanical durability of an apparatus is expressed by the number of
no-load operating cycles (each operating cycle consists of one closing and
opening operation) which can be effected before it becomes necessary to
service or replace any of its mechanical parts (however, normal maintenance
may be permitted).
Electrical durability
The electrical durability of an apparatus is expressed by the number of on-load
operating cycles and gives the contact resistance to electrical wear under the
service conditions stated in the relevant product Standard.