Part number: 106M1079-01
Manufacturer: Bently Nevada
Series: 3500
Input signal: -10 Vdc to+10 Vdc
Power consumption: 7.7 watts
Axis power supply: -24 Vdc
Product type: Transient Data Interface Module
Temperature: 25 degrees Celsius
Sensor power supply: -24 Vdc
Weight 0.82 kg (1.8 lb.)
Dimensions 241 mm x 24.4 mm x 242 mm
(9.50 in x 0.96 in x 9.52 in)
Supply situation: In stock
Repair: 3-7 days
Country of origin: United States

 


 

The provided text outlines the configuration process for the Power Supply in a 3500 Monitoring System. Here is a summary of the key points:

  1. Configuration Process:
    • Configuration involves identifying the type of Power Supply and setting operating parameters.
    • Gather configuration information and use the Rack Configuration Software to set options and download settings to the rack.
    • The Rack Configuration and Utilities Guide provides instructions on connecting a computer to the rack and running the Rack Configuration Software.
  2. Power Input Module (PIM):
    • The Power Input Module is a half-height module that connects the power source to the Power Supply.
    • Install the Power Input Module behind or above the Power Supply in a rack mount or panel mount rack.
    • Removal or insertion of a Power Input Module does not disrupt the operation of the 3500 rack as long as the other Power Supply and its associated Power Input Module are installed.
  3. Grounding Considerations:
    • To avoid ground loops, the system must have a single point ground.
    • Power Input Modules provide a switch to control the system’s grounding point.
    • If using two power supplies, set both switches to the same position.
    • A CLOSED switch grounds the system through the GND terminal on the terminal strip connector.
    • If grounding the system at another location (e.g., using internal/external barriers), ensure that the switch on each Power Input Module is OPENED.
    • Factory settings may have the switch set to CLOSED, and if internal barriers are installed, the switch may be set to OPENED.
  4. Steps to Adjust Grounding Switch:
    • Remove the line cord protection cover from the terminal strip connector.
    • Remove the Phillips screw holding the sheet metal cover on the Power Input Module.
    • Loosen the screws holding the chassis ground clip below the Terminal Strip connector and remove the clip.
    • Disengage the sheet metal tab on the bottom of the cover and slide the cover over the Terminal Strip connector.
    • Slide the chassis grounding switch to the desired position.
    • Replace the cover and the chassis ground clip on the Power Input Module.

These steps provide a guide for configuring the Power Supply and adjusting the grounding switch on the Power Input Module in the 3500 Monitoring System, emphasizing the importance of proper grounding to avoid ground loops. Users should follow these procedures for correct system operation.


Spare parts:
127610-01
AC Power Supply Module.
125840-01
High Voltage AC Power Input Module (PIM).
125840-02
Low Voltage AC Power Input Module (PIM).
01720025
Replacement Fuse (both ac PIMs).
129486-01
High Voltage DC Power Supply Module.
129478-01
High Voltage DC Power Input Module (PIM).
19
3500/15 AC and DC Power Supplies Operation and Maintenance Manual
01720025
Replacement Fuse (High Voltage DC PIM).
133292-01
Low Voltage DC Power Supply Module.
133300-01
Low Voltage DC Power Input Module (PIM).
01720045
Replacement Fuse (Low Voltage DC PIM).
129767-01
Power Supply Module Manual.