Description
3500/05-02-04-00-00-01 The data fields and their meanings are described in the following paragraphs.
The slave address and the CRC Check have the same format and meaning as
described in earlier sections.
Start Address
Start Address is the Modbus address of the first input status in the group to be
read. Note that each discrete input is allocated a Modbus Status Address. The
higher order byte is transmitted first followed by the lower order byte. The
allowed ranges are 0 to 3683 (Zero referenced). Any address outside this range
for which a status is requested will result in the exception response “ILLEGAL
ADDRESS”. See Section Error! Reference source not found. for the mapping
of the Modicon PC Registers to the Communication Gateway I/O Module
(Modbus) data.
Number of Points
This 16-bit field contains the discrete points beginning at the “Start Address”.
brand | Product Name | Product model | Order No |
BENTLY | modular | 3500/05-02-04-00-00-01 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
The format of the Read Input Status response is shown below. The response
includes the slave address, function code, number of bytes of packed discrete
points being sent and the CRC check. The discrete points are packed into bytes
with 1 bit for each status (“1” = True/ON “0” = False/OFF). The lower order bit of
the first byte of data contains the first addressed input (point) and the remainder
follows. For input quantities not a multiple of eight, the last byte will be filled with
zeros in the high order bit positions.
Read Holding Registers Command
Use this command (function code 03) to obtain the following data from the
Communication Gateway I/O Module:
Setpoint Configuration Switch Settings
Configuration Lock Alarm Event List
System Event List Rack Date and Time
Rack Reset Rack Trip Multiply – Software
Rack Trip Multiply – Hardware Rack Alarm Inhibit – Software
Rack Alarm Inhibit – Hardware Last Command Success
Full-scale Data Range Repeated 3XXXX and 1XXXX Data
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required