Description
3500/05-02-05-00-00-01 Address
Address is the 16-bit Modbus address corresponding to the register. The higher
order byte is transmitted first followed by the lower order byte. The allowed
ranges are 0 -3, 6 -13, 30 – 31, 87 – 96, and 98 (Zero referenced). Any address
outside this range will result in the exception response “ILLEGAL ADDRESS”.
See page 37 for the mapping of the Modicon PC Registers to the Communication
Gateway I/O Module (Modbus) data.
Data
Data is the 16-bit word that will be written to the address.
The data fields and their meanings are described in the following paragraphs.
The slave address and the CRC check have the same format and meaning as
described in earlier sections.
Start Address
Start Address is the 16-bit Modbus address corresponding to the starting value.
The higher order byte is transmitted first followed by the lower order byte. The
allowed ranges are 4000 – 4003, 5000 – 5500, and 6000 – 6999 (Zero
referenced). Any address outside this range will result in the exception response
“ILLEGAL ADDRESS”. See page 37 for the mapping of the Modicon PC
Registers to the Communication Gateway I/O Module (Modbus) data.
brand | Product Name | Product model | Order No |
BENTLY | modular | 3500/05-02-05-00-00-01 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
If the addressed Communication Gateway I/O Module (Modbus) receives a query
frame without a communications error and if some condition stops the
Communication Gateway I/O Module (Modbus) from responding, the interface
returns an exception response containing the appropriate error code to the
master.
The high order bit (Hex 80) of the function code field is set to “0” in a query or
normal response frame and “1” in an exception response. And regardless of the
function code, the information field of all exception response frames is one byte
long. This byte contains the exception code, defined below.
Most significant byte of the 3500 monitoring system in HEX (0D).
Family ID LSB
Least significant byte of the 3500 monitoring system in HEX (AC).
Major Rev Number
Changed when a major firmware revision occurs.
Minor Rev Number
Changed when a minor firmware revision occurs.
Modbus Application Protocol (MBAP)
MBAP is the implementation of the Modbus protocol on TCP/IP Ethernet
network. MBAP is the same as the Modbus protocol with a few minor
exceptions. These exceptions are necessary to properly operate on a non
deterministic network.
MBAP supports function code 2,3, 4, 6, and 16. All data can be read through
function codes 2, 3, and 4. All data can be written through function codes 6 and
16; however, only one value can be changed per command. Using function code
16 to write two registers is only valid for floating point values. All other writes are
for single registers.
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required