5SHY5045L0020 ABB Silicon controlled module IGCT high voltage control spare parts

Numer modelu: 5SHY5045L0020
Manufacturer: ABB
Quantity:ten
Serial ports: 4
Network ports: 7
Port isolation: 420 VDC
Weight : 3 Kg
Shipping Weight : 4 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number 5SHY5045L0020
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

Equipment likely to cause significant harmonic currents are, for example,
fluorescent lighting banks and dc power supplies such as those found in
computers (for further information on harmonic disturbances see the IEC 61000).
The reduction factors given in Table 16 only apply in the balanced three-phase
circuits (the current in the fourth conductor is due to harmonics only) to cables
where the neutral conductor is within a four-core or five-core cable and is of the
same material and cross-sectional area as the phase conductors. These
reduction factors have been calculated based on third harmonic currents. If
significant, i.e. more than 10 %, higher harmonics (e.g. 9th, 12th, etc.) are
expected or there is an unbalance between phases of more than 50 %, then
lower reduction factors may be applicable: these factors can be calculated only
by taking into account the real shape of the current in the loaded phases.
Where the neutral current is expected to be higher than the phase current then
the cable size should be selected on the basis of the neutral current.
Where the cable size selection is based on a neutral current which is not
significantly higher than the phase current, it is necessary to reduce the tabulated
current carrying capacity for three loaded conductors.
If the neutral current is more than 135 % of the phase current and the cable size
is selected on the basis of the neutral current, then the three phase conductors
will not be fully loaded. The reduction in heat generated by the phase conductors
offsets the heat generated by the neutral conductor to the extent that it is not
necessary to apply any reduction factor to the current carrying capacity for
three loaded conductors.