The following information is not required for CE compliance of a single axis installation. When planning a multi-axis installation, or if extra high frequency noise reduction is required, Pacific Scientific suggests:
· In addition to the cable requirements given in this manual the motor and signal interface cables should have a braided shield which can be grounded to reduce high frequency disturbances.
· The motor cable shield must be grounded near the drive with a suitable high frequency ground. Such a ground connection is made by removing the cable’s outer insulation, to expose the braided shield, then clamping the exposed braid to a conductive surface of the machine chassis.
If the chassis is painted or coated with another nonconductive coating, remove the coating from the clamping location prior to clamping the shield. It is important that the clamp chosen be conductive and provide a full 360 degree connection.
The signal interface cable shield should be grounded to the drive through the 9 pin D-sub connector’s conductive hood. If the cable connector does not provide a 360 degree ground connection to the shield, the signal interface cable should be grounded in accordance with the instructions given in the previous paragraph for the motor cable. For additional information please contact the factory to request: · Application Note 106 – Reducing Motor Drive Line Noise · Application Note 107 – Reducing Motor Drive Radiated Emissions.
The workstation includes an operator station and an engineer configuration station (also known as an operation station), which completes system management, configuration, process monitoring, operation, and other functions. Operator station, completing process monitoring, operation and other functions. Workstation operation permissions are divided into operator permissions and process engineer permissions. The operator has the authority to monitor the on-site instrument detection data, switch the flowchart screen, manually/automatically control the PID control circuit and modify PID parameters, manually open/close the two position on-off valve, view historical data and alarms. The operation authority of the process engineer not only includes the authority of the operator, but also allows for the setting of detection point alarm types and parameters, modification of PID parameters, and manual input range limitation of operation parameters.
Introduction to the Equipment System of Hongtai Gas Gathering Station
The Hongtai Gas Gathering Station has a total of 11 equipment, including:
5 raw material gas compressors, using SIEMENS-300 programmable controller and CP341 communication card to complete communication with the station control system:
Two flash steam compressors, using SIEMENS-300 programmable controller and CP341 communication card to complete communication with the station control system:
2 sets of ammonia refrigeration compressors, using the British Guardian SCC 40 controller, and using FPWIN software to complete communication with the station control system:
1 set of ethylene glycol system, using MINI-UPPC300 automatic control system;
1 set of thermal oil furnace system, using SIEMENS-200 programmable controller.
Recommended locator products:
1SAP111100R0170
1SAP130300R0271
1SAP140100R0100
1sap140500r3160
1SAP155500R0279
1SAP170200R0001
1SAP170700R0001
1SAP220700R0001
1SAP240000R0001
1SAP25000R0001
1SAP250100R0001
1SAP250300R0001
1SAP500405R0001
1SAR700012R0005
1SBH1360001R2344
1SBP260001R1001
1SBP260010R1001
1SBP260011R1001
1SBP260012R1001
1SBP260014R1001
1SBP260020R1001
1SBP260021R1001
1SBP260022R1001
1SBP260052R1001
1SBP260100R1001
1SBP260101R1001
1SBP260103R1001
1SBP260104R1001
1SBP260105R1001
1SBP260109R1001
1SBP260110R1001
1SBP260150R1001
1SBP260171R1001
1SBP260181R1001
1SBP260188R1001
1SBP260193R1001
1SBP260196R1001
1SBP260512R1001
1SDA054134R1
1SFA664001R1001
1SFA898116R7000
1SFB536068D1011
1SFB536068D1011,
1SNA645524R2300