Description
8910-PS-DC MTL Instrument System Power PLC/DCS
8910-PS-DC MTL Instrument System Power PLC/DCS
Open communications
MTL Open System Technologies products are just that – open. SafetyNet nodes communicate with one another, with standard MOST nodes, historian and asset management packages and with HMI packages over a fault tolerant Ethernet LAN, running at up to 100 Mbit/s.
Peer to peer communication
SafetyNet Controllers can communicate with one another via Ethernet using SafetyNet P2P – which has been certified as suitable for use in SIL 2 applications. Robust checks and controls on access and data corruption ensure the safety of communication and allow safety functions for which the inputs and outputs are widely separated to be easily implemented – both in terms of the software programming and in the hardware design.
Mixing safe and standard
Standard IO Modules can be mounted on SafetyNet Nodes – together with SafetyNet IO Modules – without affecting the node’s functional safety performance. Only standard applications can read data from standard Modules, but both standard and SafetyNet applications are allowed to write to standard modules. This flexibility can simplify hardware design, where the physical constraints of the particular locality demand such an approach.
Serial interfaces
The Open approach extends to Modbus serial interface products – which can be connected to any node (SafetyNet or standard) by an RS485 connection. As with data from standard IO Modules, this data can be read by standard Controllers, but not by SafetyNet Controllers. Both standard and SafetyNet Controllers can write to such devices.
8601-FT-NI Field terminal, non-incendive (Div 2) 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
8602-FT-ST Field terminal, standard 8618-FT-MT 16-pin Mass Termination Assembly (Div 2)
8603-FT-FU Field terminal, non-incendive, fused (Div 2) 8619-FT-MT 44-pin Mass Termination Assembly (Div 2)
8604-FT-FU Field terminal, fused 8620-FT-MT Field terminal assembly
8605-FT-TC Field terminal, thermocouple 8621-FT-IS Intrinsically Safe Field terminal, standard
8606-FT-RT Field terminal, RTD 8622-FT-IS Intrinsically Safe Field terminal, loop-disconnect
(not for 8 channel DI)
8607-FT-TC Field terminal, 8-channel with T/C 8623-FT-IS Intrinsically Safe Field terminal for 8220-DI-IS
8608-FT-NI Field terminal, 8-channel, non-incendive 8624-FT-IS Intrinsically Safe Field terminal with loopdisconnect
8610-FT-NA Field terminal, non-arcing (Div 2) 8625-FT-IS Intrinsically Safe Field terminal, THC
8611-FT-FU Field terminal, non-arcing, fused (Div 2) 8626-FT-IS Intrinsically Safe Field terminal, RTD
8612-FT-NA 16-channel Field terminal, non-arcing 8632-FT-NI 32-channel Field terminal
8615-FT-4W Field terminal, 4wire (current sinking) 8650-FT-PX 32-channel PX/Switch FTA for 8125/7
8616-FT-FU PAC8000 Field terminal, fused
8101-HI-TX 8-channel AI, 4-20mA with HART 8119-VI-05 8-channel Voltage Input, 1-5Vdc
8102-HO-IP 8-channel AO, with HART for 4-20mA 8121-DI-DC 16-channel DI, 24Vdc non-isolated, module
powered
8103-AI-TX 8-channel AI, 4-20mA 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
8104-AO-IP 8-channel AO, 4-20mA 8125-DI-DC 32-channel DI, non-isolated, modulepowered
8105-TI-TC 4-channel THC/mV input 8127-DI-SE 32-channel SOE module
8106-TI-RT 4-channel RTD input 8129-IO-DC 8-channel Supervised Discrete I/O
8109-DI-DC 8-channel DI, 24Vdc isolated, sinking 8132-AI-UN 8-channel Isolated Universal Analog Input
4-20mA, Thermocouple, RTD, Voltage
8110-DI-DC 8-channel DI, 24Vdc non-isolated, module
powered 8133-HI-TX 8-Channel Supervised AI with HART
8111-DI-AC 8-channel DI, 115Vac isolated, sinking 8139-SH-DC 126-channel Addressable Smoke and Heat
8112-DI-AC 8-channel DI, 115Vac non-isolated, module
powered 8140-DI-AC 16-channel Digital Input, 115VAC
isolated, sinking
8114-DI-AC 8-channel DI, 230Vac non-isolated, module
powered 8142-DO-DC 16-channel Digital Output, 12-42VDC, module
powered
8115-DO-DC 8-channel DO, 2-60Vdc non-isolated,
module powered 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
8117-DO-DC 8-channel DO, 2-60Vdc isolated,
unpowered 8811-IO-DC 8-Channel Safety DI/DO, 24VDC, module-powered
8118-DO-AC 8-channel DO, 20-250Vac isolated,
unpowered