FC610 is the smart feeder unit designed for ABB low-voltage switchgear digital family. The
product consists of two main parts, i.e. FC610 basic unit and the operator panel, also known
as the HMI. The separately mounted HMI from the basic unit fits perfectly in the low-voltage
switchgear modules, enabling safe operation of feeders in front of closed doors and compartments of the switchboard.
FC610 basic unit supports 3-phase 230/400V voltage measurements with a maximum phase
to phase 690Vac direct measurement, applicable in IT/TN/TT networks. The basic unit comes
with a built-in current transformer supporting 1A or 5A direct current measurement.
The measured and monitored parameters are displayed via an HMI. Upon the application, a
MP53 (compact type) may be selected to fit on a module door of each outgoing feeders while
a MP56 (full size) HMI may be selected for an incomer or a feeder fitting in a full size panel.
FC610 parameters are configured through HMI panel. Alternatively, the parameter setting
software MConfig-G can be used for remote parameterization.
In addition to the measured values listed above, FC610 provides demand values to assist the
operator to carry out energy consumption analysis and achieve increase in energy efficiency.
Demand value is the time-integrated value of the measured values. It is the average value calculated over the demand integration time.
The demand integration time in FC610 are selectable from 2 s, 10 s, 5 min, 8 min, 10 min, 15
min, 20 min, 30 min and 60 mins. The integration time is calculated by the sliding method.
The sliding time interval is 1 second when the integration time is selected as 2 or 10 seconds.
When the integration time is 5,8,10,20,30, 60 minutes, the sliding time interval is 1 minute.
For example, when 2s integration time is selected, the measured values are integrated for a 2
second time window. The sliding time interval is 1 second which means that the demand
value is calculated and updated every second.
Similarly, when 10min integration time is selected, the demand value is calculated for a
10mins period time window. The sliding time interval is 1minute which means that the demand value is calculated and updated every minute.
Maximum demand value is the maximum average value since FC610 is powered up or last reset.
The maximum demand value is resettable through fieldbus only