AO2000 LS25 abb AO2000-LS25 laser gas analyzer

¥5,820.00

AO2000 LS25

The provided information outlines the installation notes for the AO2000-LS25.

Category: SKU: AO2000 LS25 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

AO2000 LS25 abb AO2000-LS25 laser gas analyzer

 

The provided information outlines the installation notes for the AO2000-LS25. Here is a summary of the key points:

Installation Notes for AO2000-LS25:

  1. Precautions:
    • Read all instructions carefully before installation.
    • Housing parts are made of stainless steel or aluminum.
    • Grease all threads with suitable grease before installation.
    • Optical windows are factory-installed; do not remove or change their angular positions for successful alignment.
    • Disconnect mains cable or power before electrical connection.
  2. Power Connection:
    • Ensure the power plug serves as the disconnecting device, and the power socket is easily accessible.
  3. Connecting a PC:
    • Use the supplied software for service communication (compatible with Microsoft Windows®).
    • Copy the software to a separate directory on the hard disk (e.g., “AO2000-LS25”).
    • Connect the PC serial port to the RS-232 connection on the transmitter unit using the supplied serial cable and “gender changer” adapter.
      • Optionally, use a waterproof Phoenix connection cable.
      • The service program uses the serial port configured as 9600 baud, no parity, 8 bits, and 1 stop bit.
      • For network communication, connect the network cable to the Base-T connector on the transmitter unit, ensuring the serial cable is disconnected.
  4. Configuration and Parameterization:
    • Compare installation specifications with the following parameters:
      • Process gas pressure and temperature.
      • Concentration averaging.
      • Instrument time.
      • Gas concentration unit.
      • Optical path parameters.
    • Use the software to set these parameters.
  5. Normal Operation:
    • Once all necessary parameters are set, the device should enter normal operation mode and periodically update gas concentration on the LCD.

These instructions provide guidance for a successful installation and configuration of the AO2000-LS25 analyzer. If you have any specific questions or require further clarification, feel free to ask!

Contact us:

Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

 

Company Environment Introduction: