Description
In applications where a Harmony Repeater is used, the con
troller uses a default bus length of 1200 meters after the ini
tialize/format special operation 0x02 = 0000010. If the default
bus length of 1200 meters is being used then no additional
special operation is required after special operation
0x02 = 0000010; that is, special operation 0x10 = 0010000 is
not performed since it is the default (Table 3-4).
Additional proptime special operations can select one of four
proptimes (Table 3-4). The redundant controller must have the
same proptime special operation performed before its startup.
The proptime is measured at startup by both the primary and
redundant controllers. These additional proptimes allow
remote Harmony block I/Os to be located up to 3000 meters
from the local controller.
The redundant controller will red light with a
0x16 = 00010110 = LEDs 2, 3, and 5 special operation when
the selected proptime does not match the measured proptime
of the current bus master (primary controller). The configura
tion download via the redundancy link contains the primary’s
format information and stores the configured proptime in the
redundant’s format information during the download.
The block I/O uses a default bus length of 1200 meters at
startup. With Harmony block I/O firmware release E.0 or later,
the default proptime is overridden at startup when a controller
is already online and the block I/O detects a bus master
(primary controller). The proptime is then set to the measured
value to prevent a conflict. The block I/O performs a back
ground proptime check once a second. A sequential counter is
started when a valid measured value is different than the cur
rent selected value. The proptime is set to the new measured
value if the measured value remains the same for five sequen
tial checks (five seconds).
This mode of operation permits the bus to be in a nonfunc
tional state when proptime is changed for up to five seconds
after the controller has started the Hnet interface as a control
ler type. This is an acceptable state because the bus had been
previously stalled; that is, a special operation on the primary
controller with the redundant controller removed. Again, the
primary controller can change its proptime only via a special
operation and the redundant controller must be offline before
inserting the primary controller with the new proptime. The
tens digit of the FC 89 block output #31999 on the controller
reports the configured bus distance.
Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
Stock products of the same series:
DO880 3BSE028602R1 |
DATX130 3ASC25H214 |
DI810-EA 3BSE008508R2 |
CMA 132 3DDE300412 |
CTB810 HN800/CW800 |
DAPC 100 3ASC25H203 |
DAPU100 3ASC25H204 |
CPM810 |
CI532V03 3BSE003828R1 |
CI627A 3BSE017457R1 |
CP450T 1SBP260188R1001 |
CS513 3BSE000435R1 IEEE 802.3 |
CI856K01 3BSE026055R1 |
CP800 HPC800 |
CP410M 1SBP260181R1001 |
CI853K01 3BSE018103R1 |
CI854AK01-EA PRC3BSE030220R2 |
CI830 3BSE013252R1 |
B4LE 1KHL015045P0001 |
BB510 3BSE001693R2 |
BC810 3BSE031154R1 |
ASFC-01C 64649540 |
AINT-02C 64715810 |
AGPS21C GDR AGPS-21C |
APOW-01C 64605666 |
ARC093AE01 HIEE300690R0001 |
AI895 3BSC690086R1 |
AMC-DC 3ADT309900R1 |
AO895 3BSC690087R1 |
AI890 3BSC690071R1 |
AO810 3BSE008522R1 |
AO845A 3BSE045584R1 |
AOFC-02 68295459 |
AI801 3BSE020512R1 |
AI830A 3BSE040662R1 |