Sale!

ABB CT92474A Operating mode bus board

¥668.00

Part Number:CT92474A

CT92474A If there are quality issues, you can help repair them

If there is any need, please contact us and we will reply to you as soon as possible

Category: Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

In applications where a Harmony Repeater is used, the con

troller uses a default bus length of 1200 meters after the ini

tialize/format special operation 0x02 = 0000010. If the default

bus length of 1200 meters is being used then no additional

special operation is required after special operation

0x02 = 0000010; that is, special operation 0x10 = 0010000 is

not performed since it is the default (Table 3-4).

Additional proptime special operations can select one of four

proptimes (Table 3-4). The redundant controller must have the

same proptime special operation performed before its startup.

The proptime is measured at startup by both the primary and

redundant controllers. These additional proptimes allow

remote Harmony block I/Os to be located up to 3000 meters

from the local controller.

The redundant controller will red light with a

0x16 = 00010110 = LEDs 2, 3, and 5 special operation when

the selected proptime does not match the measured proptime

of the current bus master (primary controller). The configura

tion download via the redundancy link contains the primary’s

format information and stores the configured proptime in the

redundant’s format information during the download.

The block I/O uses a default bus length of 1200 meters at

startup. With Harmony block I/O firmware release E.0 or later,

the default proptime is overridden at startup when a controller

is already online and the block I/O detects a bus master

(primary controller). The proptime is then set to the measured

value to prevent a conflict. The block I/O performs a back

ground proptime check once a second. A sequential counter is

started when a valid measured value is different than the cur

rent selected value. The proptime is set to the new measured

value if the measured value remains the same for five sequen

tial checks (five seconds).

This mode of operation permits the bus to be in a nonfunc

tional state when proptime is changed for up to five seconds

after the controller has started the Hnet interface as a control

ler type. This is an acceptable state because the bus had been

previously stalled; that is, a special operation on the primary

controller with the redundant controller removed. Again, the

primary controller can change its proptime only via a special

operation and the redundant controller must be offline before

inserting the primary controller with the new proptime. The

tens digit of the FC 89 block output #31999 on the controller

reports the configured bus distance.

 

Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

Stock products of the same series:

DO880 3BSE028602R1
DATX130 3ASC25H214
DI810-EA 3BSE008508R2
CMA 132 3DDE300412
CTB810 HN800/CW800
DAPC 100 3ASC25H203
DAPU100 3ASC25H204
CPM810
CI532V03 3BSE003828R1
CI627A 3BSE017457R1
CP450T 1SBP260188R1001
CS513 3BSE000435R1 IEEE 802.3
CI856K01 3BSE026055R1
CP800 HPC800
CP410M 1SBP260181R1001
CI853K01 3BSE018103R1
CI854AK01-EA PRC3BSE030220R2
CI830 3BSE013252R1
B4LE 1KHL015045P0001
BB510 3BSE001693R2
BC810 3BSE031154R1
ASFC-01C 64649540
AINT-02C 64715810
AGPS21C GDR AGPS-21C
APOW-01C 64605666
ARC093AE01 HIEE300690R0001
AI895 3BSC690086R1
AMC-DC 3ADT309900R1
AO895 3BSC690087R1
AI890 3BSC690071R1
AO810 3BSE008522R1
AO845A 3BSE045584R1
AOFC-02 68295459
AI801 3BSE020512R1
AI830A 3BSE040662R1