Master station of intelligent spare parts module PROFIBUS of drive board DCS-CP-P ABB control card

Product name:Master station of intelligent spare parts module PROFIBUS of drive board DCS-CP-P ABB control card
Product model:DCS-CP-P
Quantity: stock on hand
Price: electricity
Product documentation: No relevant documentation

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

*LED strips: These three LED strips DCS-CP-P can be used to display REF 542plus for fast switching device load
The most relevant information obtained after a quick check. They are labeled M1, M2, and M3. Each of them is composed of 12
It consists of 10 LED lights, 10 of which are green and 2 of which are red. Under normal conditions, 10 green LED lamps
DCS-CP-P door is used to display 0% – 100% of the configured measurement rating. Thus, each LED lamp corresponds to the rated value
10% of. Two red LED lights show 20% overload status. The measured values displayed by these LED bars can
To set with the operation tool.


*Indicator LED: 8 freely programmable DCS-CP-P tricolor LEDs can be used for display. These LED lights are distributed in 4
Page. Therefore, a total of 32 indication options can be programmed for corresponding protection, control, monitoring and
Time and status related to switching value input. The operating tool allows you to assign LED lights to specific
Conditions.
*Infrared (IrDa) interface: This is an infrared serial interface, which can be used to connect the REF 542plus to the
On your PC. Using appropriate cables and operating tools, DCS-CP-P can perform the following operations:
*Download the configuration to the cell.
*Upload the current configuration from the cell.
*After a fault occurs, upload the fault recording data. Only the operating tool has enabled the fault record in advance
This operation can only be carried out after the wave.
Upload other information (measured value, switch input status, switch output status).
Do not make any changes to the configuration of REF 542plus unless you are familiar with REF 542plus
And its operating tools. Changing its configuration may lead to failure and disqualification of warranty.
*Run. When the device is running, the green LED turns on. No auxiliary power supply or equipment
When running (FUPLA is not running), the LED is off.
*Communication failure. The LED display is meaningful only when REF 542plus is equipped with a communication module. check
When the communication module is detected, the LED turns on green. If no or no communication module is detected,
The LED is displayed in red. After the Modbus communication module is installed, when the communication error rate increases, the LED becomes
Orange. When the communication error rate causes poor communication, it turns red. No communication error occurred or
When the module status register (see Modbus Technical Reference) is reset, the LED turns green.
The LED remains off when the communication module is not present.
*Alarm: When the user-defined alarm is valid, the LED turns red. The operation tool can be used to define
And configure several alarm conditions. Alarm conditions can be tripping of protection function, SF6 in circuit breaker
And so on. When the LED is on, it is not possible to close the circuit breaker or download a new configuration. first
The alarm must be acknowledged.
*Interlocking error: LED usually shows green. If the user tries to operate in violation of interlocking conditions
The LED will turn red temporarily; For example, the operation is isolated when the circuit breaker is in the closing position
Off.
The earlier HMI (HMI V4 version) of REF 542plus can still be released with
The host with version 2.5 firmware is used together, provided that the HMI firmware has been made
The corresponding upgrade has been made. After upgrading the firmware, the performance of HMI V4 is similar to that of the new international standard
HMI V5 is almost the same. Due to the low LCD resolution of early HMI
Words, such as Chinese, cannot be displayed. Other languages, such as Russian with Cyrillic alphabet,
Can be used as a first language.
The design of the new international universal HMI V5 has been improved, and the
Memory. After downloading the configuration file through the operation tool, the information files in both languages are
It can be stored on HMI. After changing the language, the language file can be displayed immediately
Now. If HMI V4 is used, the language files will be stored in the host. If you want to change
To change the display, the relevant language file must first be loaded. After LCD reset, it will display
Required language.

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen