Description
DI810 This page displays the current status of the switching value input channel on the switching value IO module. Each module has 14
Switch input. For information about the number of switching value inputs, refer to Section 19.2. Switching value inputs and
Output.
Line description: “channel descriptor”, “channel number”, “value”
DI810 channel descriptor: switching value input
Channel number: x-yy. X represents the switching value IO slot, and yy represents the switching value input number. 1 represents X20 slot
Mouth, and so on.
Value: 0 → input is not active. The applied voltage is lower than the starting critical value.
1 → Input active. The applied voltage is higher than the starting critical value.
In this page, you can forcibly change the switch output state. All outputs can be driven except watchdog
Quantity.
Line description: “channel descriptor” “channel number:” value ”
Channel descriptor: switching value input
Channel number: x-yy. X represents the switching value IO slot, and yy represents the switching value output number. 1 represents X21 connection
And so on.
Value: 0 → output opening. The relay is not energized.
1 → Output closing. The relay is energized. Normally, DI810 open contacts will be closed
upper
This page displays the analog measurement value obtained by the analog input module. Display value is independent of primary transmission
Rated primary current or voltage of the inductor. Considering that the nominal value of secondary coil is 1Amp and 100V, report
The measured value of is absolute. If the current input of 5Amp is displayed with the nominal rated current, it will
Is displayed as 1A.
When the alarm LED is on, downloading is prohibited.
Click the relevant button on the operation tool to start downloading the configuration.
The original configuration in REF 542plus will be destroyed and overwritten by the new configuration.
During the download, the REF 542plus is fully operational. After downloading, REF 542plus will
Write the new configuration in the non-volatile memory. The task runs in the background and has a lower priority.
This task can last several seconds.
The DI810 must not power off the head unit during storage. Otherwise, the whole equipment configuration may be damaged
So you need to download the new configuration.
The protection status is switched to the operation mode through the electronic key and can be downloaded under all control modes.
During downloading, communication with SCADA system is still available.
After downloading, REF 542plus will automatically start with the new configuration.
After downloading, the device can
It can change the operation state of output relay. It is strongly recommended that you open the
Switch the device to safety mode.