Sale!

ABB DI880 3BSE028586R1 Drive Extender Bus Module

¥668.00

Part Number:DI880 3BSE028586R1

DI880 3BSE028586R1 If there are quality issues, you can help repair them

If there is any need, please contact us and we will reply to you as soon as possible

Category: Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Tests Hnet communication when an RFO Fiber Optic Repeater is

between a master and a controller acting as an I/O device. Checks

the ability to both transmit and receive Hnet messages. Requires

two controllers (redundant or primary) and the appropriate PBA,

Hnet cabling, and termination hardware. Set one controller to test

16 (master); the other to test 21. Both controllers provide pass/fail

indication.

NOTE: A Harmony block I/O set at test 21 can also serve as the

I/O device. This is the recommended setup for testing Hnet.

Unused 18-1F —

Group test 2 20 Executes tests 01 through 1F.

IISAC01 station and

redundancy link

redundant

22 Displays running count of bytes received by redundant controller

when primary controller is executing test 20. Provides the common

functionality of both tests 23 and 24.

I/O expander bus

fault time halt 2

25 Arms the fault timer and allows the I/O expander bus clock to stall.

This checks the controller ability to disengage from the I/O

expander bus in the event it can no longer drive the expander bus

clock. This test passes if controller halts with a 0x55 pattern dis

played on the LEDs. Fails if controller continues to operate with

any other pattern displayed on the LEDs.

NVRAM retention –

data storage 2

26 Stores a known data pattern in NVRAM for testing by the NVRAM

retention – data check test 27. Halts with LED pattern 0x55 if test

has completed writing data.

NOTE: Remove power from controller prior to running the NVRAM

retention – data check test. If practical leave controller unpowered

for one hour prior to running the data check test.

NVRAM retention –

data check

27 Verifies NVRAM holds data pattern stored in test 26. Provides nor

mal pass/fail indication.

Redundancy link

break

28 Tests redundancy links ability to generate and detect a break in the

transmission. An intentionally generated break is sent. The

receiver detects the break and in response sends a break back.

Requires two controllers (redundant) and the appropriate redun

dancy cabling. Set both controllers to test 28.

Stop pushbutton 2

29 Verifies proper pushbutton operation. Passes if after pressing the

stop pushbutton once, LED display changes from 0x29 to 0x55

with the red/green LED red.

 

Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

Stock products of the same series:

DSAI 146 3BSE007949R1
DO810 3BSE008510R1
DSAI 133A 3BSE018290R1
DO880 3BSE028602R1
DATX130 3ASC25H214
DI810-EA 3BSE008508R2
CMA 132 3DDE300412
CTB810 HN800/CW800
DAPC 100 3ASC25H203
DAPU100 3ASC25H204
CPM810
CI532V03 3BSE003828R1
CI627A 3BSE017457R1
CP450T 1SBP260188R1001
CS513 3BSE000435R1 IEEE 802.3
CI856K01 3BSE026055R1
CP800 HPC800
CP410M 1SBP260181R1001
CI853K01 3BSE018103R1
CI854AK01-EA PRC3BSE030220R2
CI830 3BSE013252R1
B4LE 1KHL015045P0001
BB510 3BSE001693R2
BC810 3BSE031154R1
ASFC-01C 64649540
AINT-02C 64715810
AGPS21C GDR AGPS-21C
APOW-01C 64605666