DO818 industrial control DCS system circuit board control processing module

Product name:DO818 industrial control DCS system circuit board control processing module
Product model:DO818
Quantity: stock on hand
Price: electricity
Product documentation: No relevant documentation

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

DO818 To copy an application from one CP450 to another CP450, select F3 – Copy
from the system menu. Set the dip switch SW7 = ON and connect the two operator terminals with a download cable. After the self-test, the system menu will
be displayed on the screen.


Select F3 – Copy in the system menu from the operator terminal with the application to be copied. DO818 The operator terminal will prompt for a password: enter the
password set in CP400Soft from Application/Workstation Setup. Once the correct password is entered, the CP450 starts to copy the application to the other
CP450.
For information about setting a password, please see section 7.10 Passwords.
The following appears on the screens during the copying:

Scenario 1: Requiring a password to start the operator terminal
If the dip switch SW6 = ON, the user needs to enter a password to start the
operator terminal. For this purpose, the designer can use the object Action
Button in CP400Soft to create a button which displays the password table on
the operator terminal display. A user with the right to DO818 access the table can register
passwords and user levels in the table.
In the illustration below, the button is an action button used to display the
password table. When the button is selected the password table is displayed on
the screen for a user with the right to access the table. DO818 Touch the password to
highlight an area for entering a value.

How to configure an Action Button is described in the CP400Soft User’s
Manual.
After registering passwords and user levels, set the dip switch SW6 = ON
(i.e. password required). Restart the operator terminal and after the self-test the
user will be prompted to enter a password in order to run the operator terminal.
The operator terminal will determine the user level from the entered password.
For instance, if the level of the password entered by the user is 2, then the operator terminal will set the user level to 2. User level 1 has the highest privilege and
User level 9 has the lowest.

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen