Description
Manufacturer | ABB |
Brand | ABB |
Series | module |
Part NumberDPW01 | |
Product Type | module |
Quality | 100% New Original |
Stock | In stock |
Delivery time | 1-3 days after Payment |
After-sales Service | Have |
Warranty | 1 year |
Shipping term | DHL / FEDEX/ EMS /UPS/TNT/EMS |
Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Transmission parameter ACS355 Transmission setting description
9802 COMM PROT SEL 4=EXT FBA allows
Communication between.
5101 FBA TYPE PROFIBUS-DP1) shows the model number of the Fieldbus Adapter Module.
5102 FB PAR 2
(NODE ADDRESS)
42) Define the
PROFIBUS node address.
5103 FB PAR 3
(BAUD RATE)
15001) Display the current baud of the PROFIBUS network
Rate in kbit/s.
5104 FB PAR 4
(TELEGRAM TYPE)
4 (=PPO4) 1) Display the message type selected by PLC configuration tool
Type.
5105 FB PAR 5
(PROFILE)
1 (=ABB DRIVES) Select the control word according to ABB transmission configuration.
3018 COMM FAULT FUNC 3=LAST SPEED allows monitoring of field bus communication failures.
3019 COMM FAULT TIME 3.0 s defines the monitoring time of field bus communication interruption.
5401 FBA DATA IN 1 4 (=SW 16bit) 1) Status word
5402 FBA DATA IN 2 5 (=Act1 16bit) 1) Actual value 1 (speed)
5403 FBA DATA IN 3 6 (=Act2 16bit) 2) Actual value 2 (torque)
5501 FBA DATA OUT 1 1 (=CW 16bit) 1) Control word
5502 FBA DATA OUT 2 2 (=Ref1 16bit) 1) Given 1 (speed)
5503 FBA DATA OUT 3 3 (=Ref2 16bit) 2) Given 2 (torque)
5127 FBA PAR REFRESH 1=REFRESH FPBA-01 configuration parameter setting takes effect.
9904 MOTOR CTRL
MODE
2 = VECTOR:
TORQ
Select vector control mode as motor control mode
Equation.
1001 EXT1 COMMANDS 10=COMM selects field bus interface as external control ground
Signal source for start and stop commands of 1.
1002 EXT2 COMMANDS 10=COMM selects field bus interface as external control ground
2. Signal source of start and stop commands.
1102 EXT1/EXT2 SEL 8=COMM allows to select external control ground through field bus
1/2。
1103 REF1 SELECT 8=COMM selects Fieldbus given 1 as speed given
1.
1106 REF2 SELECT 8=COMM selects Fieldbus given 2 as speed given
1.