  • DSTA180 DSTA180F These setpoints describe the characteristics of each transformer winding and the CTs

    connected to them.

    Note

    The above setpoint options are also available for the second and third winding. Winding 3

    setpoints are only visible if the unit has the appropriate DSTA180 DSTA180F hardware and if the selected

    TRANSFORMER TYPE is a three-winding transformer.

  •  

    WINDING 1(3) NOM Φ−Φ VOLTAGE: Enter the nominal phase-to-phase voltage rating

    of Winding 1(3) of the transformer. The range for this setpoint is affected by the S2

    SYSTEM SETUP TRANSFORMER  LOW VOLTAGE WINDING RATING setting (see table

    below).

    WINDING 1(3) RATED LOAD: Enter the self-cooled load rating for winding 1(3) of the

    transformer. The range for this setpoint is affected by the S2 SYSTEM SETUP

    TRANSFORMER  LOW VOLTAGE WINDING RATING DSTA180 DSTA180F setting (see the table below).

    WINDING 1(3) PHASE CT PRIMARY: Enter the phase CT primary current rating of the

    current transformers connected to winding 1(3). The CT secondary current rating must

    match the relay phase current input rating indicated.

    WINDING 1(3) GROUND INPUT SELECTION: Select the ground CT (G1/2 or G2/3) for

    the particular winding required. Leave ground CT selection at default value of “None” if

    no CT is needed on the required winding.

    The ground input selection settings will be defaulted to “None” when an upgrade

    settings file is uploaded.

  • Whenever transformer type is changed (particularly from 2 W to 3 W) “ground input

    selection” setting should be cross-checked.

    WINDING 1(3) GROUND CT PRIMARY: DSTA180 DSTA180F Enter the ground CT primary current rating of

    the current transformers connected in the winding 1(3) neutral to ground path. The CT

    secondary current rating must match the relay ground current input rating indicated.

    WINDING 1(3) SERIES 3-Φ RESISTANCE: Enter the series three-phase resistance of the

    winding (that is, the sum of the resistance of each of the three phases for the winding).

    This value is normally only available from the transformer manufacturer’s test report,

    and is used in the 745 for calculation of harmonic derating factor.