FAU810 Flame analysis pre/monitoring spot ABB, Sweden

Product name: FAU810 Flame analysis pre/monitoring spot ABB, Sweden
Product model:FAU810
Quantity: stock on hand
Price: electricity
Product documentation: No relevant documentation

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

  • FAU810 Protection and monitoring elements are configured in this page. This includes complete

    differential protection; phase, neutral, ground, negative sequence overcurrent; restricted

    ground fault (differential ground); under, over, and rate-of-change of frequency;

    overexcitation; harmonic monitoring; analog FAU810 input monitoring; current demand

    monitoring; and transformer overload monitoring.

  •  

    Each element is comprised of a number of setpoints, some of which are common to all

    elements. These common setpoints are described below, avoiding repeated descriptions

    throughout this section:

    Following the setpoint descriptions are logic diagrams illustrating how each setpoint, input

    parameter, and internal logic is used in a feature to obtain an output. The logic diagrams

    are organized into the following FAU810 functional blocks:

    <NAME OF ELEMENT>

    FUNCTION: Enabled

    Range: Disabled, Enabled

    Select “Enabled” to enable the element. For critical protection

    elements, this setpoint is normally “Enabled” except for test

    purposes. For elements FAU810 which are not to be used, this

    setpoint should be set to “Disabled”.

    <NAME OF ELEMENT>

    RLYS (1-8):

    Range: 1 TO 8

    Select output relay to be configured for the element.

    <NAME OF ELEMENT>

    TARGET: Latched

    Range: Self-reset, Latched, None

    Target messages indicate which elements have picked up or

    operated. Select “Latched” to keep the element target

    message in the queue of target FAU810 messages, even after the

    condition which caused the element to operate has been

    cleared, until a reset command is issued. Select “Self-reset” to

    automatically remove the target message from the message

    queue after the condition has been cleared. Select “None” to

    inhibit the display of the target message when the element

    operates. An element whose target type is “None” will never

    disable the LED self-test feature because can not generate a

    displayable target message.

    <NAME OF ELEMENT>

    BLOCK: Disabled

    Range: Disabled, Logc Inpt 1 to 16, Virt Inpt 1 to 16, Output

    Rly 1 to 8, SelfTest Rly, Virt Outpt 1 to 5

    Select any logic input, virtual input, output relay, or virtual

    output which, when asserted or operated, blocks the element

    from operating. Selecting a logic or virtual input allows

    blocking the element based on a decision external to the 745.

    Selecting an output relay or virtual output allows blocking the

    element based on conditions detected by the 745 and the

    combination of logic programmed in the associated

    FlexLogic™ equation.