GDB021BE/HIEE300766R1 ABB short order cycle spot analog quantity module

Product name: GDB021BE/HIEE300766R1 ABB short order cycle spot analog quantity module
Product model:GDB021BE
Quantity: stock on hand
Price: electricity
Product documentation: No relevant documentation

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

GDB021BE Based on the rules given above, the output relay 2 FlexLogic™ equation is shown above.

On the left is a stack of boxes showing the FlexLogic™ messages for output relay 2. On the

right of the stack of boxes is an illustration of how the equation is interpreted.

In this example, the inputs of the four-input OR gate are Percent Diff OP, Inst Diff OP, the

output of the XOR gate, and the output of the AND gate. GDB021BEThe inputs of the two-input AND

gate are the output of GDB021BE the NOT gate, and Output Relay 2. The input to the NOT gate is Logic

Input 2. The inputs to the two-input XOR gate are Virtual Output 1 and Logic Input 1. For all

these gates, the inputs precede the gate itself.

This ordering of parameters of an equation, where GDB021BE the gate (or “operator”) follows the input

(or “value”) is commonly referred to as “postfix” or “Reverse Polish” notation.

This section contains the settings (including the FlexLogic™ equation) to configure output

relays 1 to 8.

OUTPUT 1(8) NAME: Press ENTER edit the name of the output. The text may be

changed from “Solid State Trip” one character at a time, using the VALUE keys. Press

ENTER to store the edit and advance to the next GDB021BE character position.

OUTPUT 1(8) OPERATION: Select “Latched” to maintain the output 1(8) contacts in the

energized state, even after the condition that caused the contacts to operate is

cleared, until a reset command is issued (or automatically after one week). Select “Self

reset” to automatically de-energize the contacts after the condition is cleared. The

solid state output (output 1) remains closed until GDB021BE externally reset by a momentary

(outputs 2 to 8) in which case it turns off when the relay operates.

OUTPUT 1(8) TYPE: Select “Trip” to turn the Trip LED on or “Alarm” to turn the Alarm

LED on when this output operates. Otherwise, select “Control”. Note that the Trip LED

remains on until a reset command is issued (or automatically after one week). The

Alarm LED turns off automatically when the output is no longer operated.

OUTPUT 1(8) FLEXLOGIC 01 to 20: The twenty (20) messages GDB021BE shown in the table below

are the parameters of the FlexLogic™ equation for output 1(8) as described in the

introduction to FlexLogic™.

Note

The relays can also be energized from individual protection elements

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen