Description
Typically the two operator station function is used for a crane that is controlled by a radio remote unit and a local
console on board the crane.
Actuation of a Process DI will:
- Make the ASTAT taking command from either of the two stations.
- The indications (DO and AO) will remain for both stations at the same time.
The change of operator station is only allowed to change when the system is OFF.
Process I/O digital input no.3 can be used in two ways:
3) To select between operator stations
4) To make the selection between parameter sets 1 or 2 (Low sets family) or parameter sets 3 or 4 (High sets
family)-selection within the family is done by Process I/O digital input no.4.
With 05.27 = 0, a high value (=110 V) on DI no.3 on process I/O board DATX 110 will use DI no.3 to select between
operator station number two out of number one and number two.
With 05.27 = 1, a low value (=0 V) on DI no.3 on process I/O board DATX 110 will use parameter sets 1 and 2. The
selection between Sets 1 and 2 is made with DI no.4.
With 05.27 = 1, a high value (=110 V) on DI no.3 on process I/O board DATX 110 will use parameter sets 3 and 4.
The selection between Sets 3 and 4 is made with DI no.4.
NB! Do not mix this function with Shared motion, although related. The second parameter set function is typically used
for redundant motions, there, as an example; the acceleration ramps are lower when only half of the motors are used.
All uncontrolled stops of a crane should by subject to investigation. Typical reasons for uncontrolled stops are Over
speeding a hoist, Hitting upper safety limit switch or an Emergency stop push-button is pressed during run. In all
cases the reason should be reported and the reason should if possible be prevented from being repeated. Exam
ple of measures: The working limit switch and the safety limit switch should be separated in distance, Instructions
should be given how to use the emergency stops.
Frequent electrically uncontrolled stops will increase the wear of the crane considerably.
An uncontrolled stop is defined by loosing the crane contactors on-state annunciation signal while the brake is
lifted by the ASTAT control system. This supervision is turned on with parameter 22.03.
If the above state is declared DO no. 8 of DATX 110 will open. It cannot be closed or the ASTAT will not be ready
for new service until the 230 (115) V AC control voltage has been off and on again.
See also Sections 2.3 Crane power and control voltage.
This function is not available for share motion drives.
This function is available from AST10_03A.
Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
Stock products of the same series:
IOD86MEM |
IOD86-TR |
IORE63-20-CC |
KTO1140 |
LD 800 HSE |
LD MTR-01 63940135F |
LD MUI-01 61320946C |
LD SYN-101 3BHE005555R0101 |
LD800HSE 3BDH000320R02 |
LDGRB-01 3BSE013177R1 |
LDMUI-001 61320946C |
LDSTA-01 |
LDSYN-101 3BHE005555R0101 |
LF 1005-S/SP16 |
LT 370C GJR2336500R1 |
LT C391 AE01 HIEE401782R0001 |
LTC743CE22 3BHE013299R0022 |
LXN 1604-6 3BHL000986P7000 |
LXN1604-6 |
MCM800 |
MFS3N-230V |
MNTU-21C 3BSE017429R1 |
MP9-20976K 3*174UF |
MPM810 |
MPRC086318-501 |
MPRC086406-502 |
MTA0020 HB010662R0120 |
MTS1-10B 1SFA611300R1006 |
NAIO-01 |
NAIO-02 |
NAMC-03C |
NAMC-11 3BSE015488R1 |
NBIO-21C 3BSE017427R1 |
NBRA-659C 59006436 |
NC4672A V1 HIEE205012R1 |
NCAN-02C 64527932 |
NCHM-21 |
NCHM-21C |
NCSA-01 58920002 |
NDBU-95 |