Sale!

ABB PFSK142 3BSE006505R1 Robot circuit board

¥668.00

Part Number:PFSK142 3BSE006505R1

PFSK142 3BSE006505R1 If there are quality issues, you can help repair them

If there is any need, please contact us and we will reply to you as soon as possible

Category: Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

The digital outputs will be set to a predetermined value if the OSP-watchdog timer

expires or if the SetOSPState command is received. The watchdog timer is re

triggered every time the correct module address has been decoded (or broadcast). If

the watchdog timer expires or if the SetOSPState command is received, the module

enters the OSP state.

The function in OSP state, and when reentering the operational state, will be

different depending on how the DO function is configured (see Digital Output 1 – 4

above):

  1. Function in OSP state: No more pulses will be activated as long as the module

remains in OSP state. The DO pulse is always completed if the OSP-state is

entered during an active DO pulse (this is, the pulse width is always in

accordance with the DOTIME value).

Function when reentering operational state: The coincidence function has to be

enabled before normal DO function will start.

  1. Function in OSP state: Same as in 1. above. Function when reentering

operational state: A new DO-pulse will be started as soon as a modulebus

frame with DOVALUE=1 is received.

  1. Function in OSP state: The digital outputs are set to their OSP values which

can be configured as a predefined value or to use last good value sent.

Function when reentering operational state: The outputs keeps the OSP value

until a modulebus frame with a new DOVALUE value is received.

Each channel has inputs for 12 V, 24 V and NAMUR input signals and a

configurable transducer power output. The configurable transducer power is set on

module (not channel vise) for all channels to either NAMUR, 12 V or 24V.

The module distributes the external transmitter supply to each channel. This adds a

simple connection to distribute the supply to 2-wire or 3-wire transmitters. The

transmitter power is supervised and current limited. The inputs can be supervised

for short circuit and open wire. The supervision can be enabled/disabled per module

(not channel vise).

The transducers should be connected by shielded twisted pair cable if the used filter

time is less than 800μs.

The MTU have to be chosen with consideration to function and signal range, see

Table 100. Type of sensor to be used is defined by parameters.

The parameter set the sensor power output for NAMUR sensors to 8.2 V, for 12 V

sensors to 12 V and for 24 V sensors to 24 V.

 

Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

Stock products of the same series:

PPD512A10-15000 3BHE040375R1023
PPD115A102
PPC902CE101
PPC902AE101 3BHE010751R0101
PPA322B HIEE300016R2 HIEE400235R1
PP885 3BSE069276R1
PP875 3BSE092977R1
PMA323BE HIEE300308R1
PM820-2
PM820-1
PFVI401
PFTL301E
3BSE004166R1
PFSK164 3BSE021180R1
PFSK162 3BSE015088R1
PFSK160A 3BSE009514R1
PFSK142 3BSE006505R1
PFSK130 3BSE002616R1