Sale!

ABB PFVI 102 YM110001-SN Transformer power supply

¥668.00

Part Number:PFVI 102 YM110001-SN

PFVI 102 YM110001-SN If there are quality issues, you can help repair them

If there is any need, please contact us and we will reply to you as soon as possible

Category: Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Pulse count is done by pulse accumulation in a 16 bit pulse counter. The pulse

counter value is continuously loaded into the pulse register.

The value of the pulse register (that is, actual pulse count value) is read by the CPU,

and transferred to the ModuleBus master.

Frequency (speed) Measurement.

The frequency measurement function consists of two counters, that is, the SX and

SR counters. The SX counter is used to count number of pulses (Sx) from the

unknown input frequency. The SR counter is used to count the number of pulses (Sr)

from a reference frequency source with frequency FREF. The frequency value (Fx) is

calculated as:

Fx = FREF x Sx / Sr

The SX counter is implemented by a 12 bit up-counter. The SR counter is

implemented by a 20 bit up-counter.

 

The SX and SR counters accumulates pulses during a measurement period.

The measurement interval for each channel defined by the user to 10 ms, 20 ms,

50 ms or 100 ms. By changing the measurement interval the user can select a

suitable filter time (integration time) with respect to the application’s requirements.

At the end of each measurement period are the SX and SR registers is updated with

the value of the SX and SR counters. The CPU reads the content in the SX and SR

registers and calculates a frequency value.

The reference counter (SR) has a overflow detection function. The SR overflow will

be activated if no incoming pulses has been detected during 3 s. When the CPU

detects SR overflow, is the frequency value set to zero.

Redundant Applications

In a redundant application one module is set to primary and one to backup. The

primary module synchronize the counter on the backup module every 10 seconds.

After start-up it will take about 30 s before the backup has been synchronized

 

Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

Stock products of the same series:

ABB NTAI05
ABB NTDI01
ABB PCU-03
ABB PFBI 161
ABB PFBK 164
ABB PFBK162 3BSE000472R1
ABB PFBK164 3BSE000469R1
ABB PFBK165 3BSE000470R1
ABB PFEA111-65 3BSE050090R65
ABB PFEA112-65
ABB PFEA113-20
ABB PFVI102
ABB PM150V08
ABB PM151 3BSE003642R1
ABB PM154 3BSE003645R1
ABB PM511V08
ABB PM783F
ABB PM825
ABB PM851AK01
ABB PM856
ABB PM856AK01
ABB PM861AK02
ABB PM864AK02
ABB PM866K01
ABB PM866K02
ABB PP C905 AE101
ABB PP30012HS
ABB PP836A
ABB PP865A 3BSE042236R2
ABB PU514A
ABB Q3E-041652
ABB RDCO-02C
ABB rdcu-12c
ABB REM615
ABB RER620
ABB RFO-800
ABB RHC931
ABB RVC8-1/5A
ABB S263-B10
ABB S263B10-400
ABB SA801F
ABB SA811F
ABB SACE PR112/P-A
ABB SAFP 25
ABB SAFT 110
ABB SAFT 111 POW
ABB SAFT 120
ABB SAFT 121
ABB SAFT 125
ABB SAFT 136
ABB SAFT 138
ABB SAFT 160F 380
ABB SAFT 171 PAC