Description
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also
generates the correct address to the I/O module by shifting the outgoing position
signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O
modules. This is only a mechanical configuration and it does not affect the
functionality of the MTU or the I/O module. Each key has six positions, which gives
a total number of 36 different configurations. The configuration can be changed
with a screwdriver.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that
locks the MTU to the DIN rail. The latch can be released with a screwdriver.
The MTU has a mechanical locking mechanism that locks the module in its
position. This mechanism also gives the signal BLOCK to the I/O module that keeps
the module in its init state until it is locked in its position.
The process signal terminals are divided into 2 equal and individually isolated
groups. Each group consists of 8 I/O connections, one process voltage connection
and 5 common L- connections.
The top part of the MTU can be removed to replace the termination board even with
an operational system. Such a need can be caused by a damaged terminal screw.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also
generates the correct address to the I/O module by shifting the outgoing position
signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O
modules. This is only a mechanical configuration and it does not affect the
functionality of the MTU or the I/O module. Each key has six positions, which gives
a total number of 36 different configurations. The configuration can be changed
with a screwdriver.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that
locks the MTU to the DIN rail. The latch can be released with a screwdriver.
The MTU has a mechanical locking mechanism that locks the module in its
position. This mechanism also gives the signal BLOCK to the I/O module that keeps
the module in its init state until it is locked in its position.
The process signal terminals has 8 individually isolated I/O channels. Each channel
has two connections.
The TU811/TU811V1 is primarily intended for modules with individually isolated
channels.
The top part of the MTU can be removed to replace the termination board even with
an operational system. Such a need can be caused by a damaged terminal screw.
Details: If you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.
Price issue: If you find that other suppliers offer a cheaper price for the same product, we are also willing to provide you with a reference price and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
Stock products of the same series:
PFTL201D 10KN |
PFTL201D 20KN |
PFTL201D 50KN |
PFTL201DE 10KN |
PFTL201DE 20KN |
PFTL301E |
PFTL301E 1.0 KN |
PFTL301E 3BSE019050R1000 1.0KN |
PFTL301E-0.5KN |
PFVI401 |
PFXA401SF |
PFXA401SF |
PG-B3 |
PGR-4C-E |
PH1003-2840 |
PH266-01GK-C5 |
PH-3A |
PHAREPRFO10000 |
PHARPS03000000 |
PHARPS32000000 |
PHARPS32000000 |
P-HA-RPS-32000000 |
P-HA-RPS-32000000 |
P-HA-RPS-32000000 |
PHARPS320000000 |
PHARPS32010000 |
PHARPS32200000 |
P-HA-RPS-32200000 |
P-HA-RPS-32200000 |
P-HA-RPS-32200000 |
PHARPS32200000 F8-G2B9B3B6 |
PHARPSCH100000 |
PHARPSCH100000 |
PHARPSFAN03000 |
PHARPSFAN03000 |
PHARPSPEP21012 |
PHARPSPEP21013 |
P-HA-RPS-PEP21013 |
PHBAIN1200S100 |
PHBAIN2200S100 |
PHBAOT1500S100 |
PHBBLK10000100 |
PHBBLK10010000 |
PHBDIO4000R100 |
PHBDOT1000S100 |
P-HB-IOR-8000N200 |
PHBRMU1000N100 |
PHBRMU10010000 |
PHCBRCPBA10000 |
P-HC-BRC-PBA200 |
PHG491LD7200J |
PHKRMPBA2000A |
PI3381 Triconex |