PM866A The Isolate-Not is a composite signal that represents a number of control unit states in the

control unit that should result in branch isolation. Isolate is negated (goes low) as a result of

system malfunction (see previous chapters on system diagnostics), a manual request for

maintenance purpose, or when a test reveals a fault that must be handled by disabling the failing

branch. This is particularly applicable to NE outputs.

The Isolate signal is timed so the loss of a control PM866A unit or an output board will always cause a

low Isolate signal to be recognized first. The shutdown output is timed to go low after isolate to

prevent it from requesting a shutdown when the isolate is still high.

In a similar fashion, the isolate is designed to return high after a valid signal is presented on the

shutdown output to prevent spurious action on PM866A system restart or isolate removal. This function

allows fault tolerant action to be taken on failure or during maintenance.

Shutdown-Not or Activate

The Shutdown-Not (Normally Energized) or Activate (Normally De-Energized) signal is a

combination of an application generated action, PM866A manual action and signals from the test

program. It is also affected by system errors, and is forced low (NE) or will stay low (ND) on a

control unit malfunction.

Master Vote 3000 automatic output tests are performed as a part of the Safeguard 400 Series

base software and consists of:

The output tests consist of:

  • Channel test
  • Isolate test
  • Option for monitoring of read-back of the output status.
  • Option for feedback of the output loop supervision signal.

The basic test uses the Isolate-Not and Shutdown-Not (NE) / Activate (ND) signals to control

the test, and receives information back on two inputs (Isolate Status and Test Status). These are

common to all seven outputs on one Master Vote 3000 unit. The standard tests cover all

functions of the Master Vote 3000. The PM866A normal action for a NE output on detection of a fault is

to isolate the branch by deactivating Isolate-Not, and report this as a safety message and on the

diagnostics displays. ND stays low.

2.1.7 Bypass Management

The functions of Bypass management are:

  • Operator station access control
  • On-Line Builder (engineering tool) access control
  • Override control and reset

Override is generally used as a collective term for inhibit, input block, output block and manual

mode for the relevant signal types.

The use of override functions in safety related equipment introduces a potential hazard to the

installation and to the people it is designed to protect. Any inhibit of a safety critical input or

override on a safety critical output represents a degradation of the safety level and a possibility

for failure on demand.

Nevertheless, such functions are necessary to achieve a reasonable availability of the process.

All field equipment needs maintenance or replacement at regular intervals, and this is included

in the design of the safety system regarding e.g. number/wiring and placement of instruments.

In these cases the safety level may be maintained by other measures while necessary

maintenance operations are carried out.

There are also requirements for use of inhibits during start-up in certain applications.

The Bypass management function enables project/application specific configuration of the

appropriate level of restrictions regarding operation of the Safeguard 400 Series.

2.1.7.1 Operator station access control

Operator stations which shall be accepted for write access must be configured in the Safeguard

400 Series and a key switch shall be hard wired to the Safeguard 400 Series for control of

permission to operate the system.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen